required load and speed of actuator. 8. Load Cell: Static capacity 630kN and dynamic capacity 500kN (fatigue rated not less than 1 million cycles, Class 0.5% or.
Indian Institute of Technology Bombay MATERIALS  MANAGEMENT  DIVISION

 Direct : (+91­22) 2576 8800 (DR) / 8803 (Local) / 8804 (Import) /  8805  (Enquiry & Bill tracking), 8802(Progress)  Email : [email protected][email protected] 

ANNEXURE-1 Specifications for Static and Dynamic Structural Testing System S No. 1

Particulars Servo-hydraulic Actuators

1. 2. 3. 4. 5. 6.

7. 8.

Technical Requirement Application: Static, Dynamic and Fatigue Quantity: 2 Nos. Capacity: Dynamic +/- 500kN; Stroke: +/- 125mm (250mm total) Type: Double acting fatigue rated actuator with load cell and built in LVDT. Swivel Ends: Base and Head swivel assembly suitable for actuators to conduct tension, compression and thro-zero cyclic load test with no free play. Servo valves: 56 lpm or better (two valves on each actuator, Moog make) to achieve the required load and speed of actuator. Load Cell: Static capacity 630kN and dynamic capacity 500kN (fatigue rated not less than 1 million cycles, Class 0.5% or better). Calibration certificate in-house and third party to be provided in both Tension and Compression mode. Sensitivity: 2-3mV/V or better. Detailed technical specifications to be provided.

9. LVDT: Stroke +/- 125mm. Calibration certificate in-house and third party to be provided. Sensitivity: 80-100mV/V/mm or better. Detailed technical specifications to be provided.

10. Other accessories: Lifting shackles, Servo valve manifold, Load cell attachment, Swivel attachment, Flushing block and adapter plates, Hydraulic accumulators, etc. Full details of each component to be provided wherever necessary.

2

Hydraulic Power Unit

1. Operating Pressure: 21 MPa (3000 psi) 2. Flow Rating: 200-300 lpm (or better, suitable

Indian Institute of Technology Bombay MATERIALS  MANAGEMENT  DIVISION

 Direct : (+91­22) 2576 8800 (DR) / 8803 (Local) / 8804 (Import) /  8805  (Enquiry & Bill tracking), 8802(Progress)  Email : [email protected][email protected] 

for driving two actuators at a time) 3. Hydraulic Service Manifold: To share a single Hydraulic Power Unit with two actuators independently. 4. Other Requirements: Low noise-better than 68dB(A), Electrical power 415 VAC/3Ph/50Hz, Suitable pressure and return line filter, Water cooled with suitable heat exchanger, Reservoir capacity 950 liters or better, Hose pipes set for Pressure, Return and Drain line (about 10m or more in length), Hydraulic Oil, etc. Full details of each component to be provided wherever necessary.

3

Digital Controller Software

&

System 1. PC based Digital Controller capable to control four actuators independently and simultaneously. 2. System update rate: 4096 Hz or better 3. Servo control mode: Load, Stroke and Strain. 4. Control loop tuning: Manually or Automatic 5. Signal generation: Frequency 0.001 to 500 Hz with 32 bit resolution and capable to generate various waveforms like Sine, Haversine, Square, Triangular, Ramp, Random, Sine-sweep, etc. 6. Valve Drive: 2 stage or 3 stage 7. Digital Universal Conditioner: For Load cell, LVDT, Strain Gauges or Strain Gauge based sensors; Excitation Voltage selectable; Excitation Frequency selectable; Low noise; Low drift; High accuracy; 8. Signal Acquisition: High sampling speed (better than 100 KHz simultaneously); Digital Filters; Resolution 19 Bits or better; Data transfer in various formats like ASCII, MTS RPC, MATLAB, UFF, BUFF and others; 9. Analogue Input: 2-4 channels 10. Analogue output: 2-4 channels 11. Power input: Single Phase 240VAC – 50 Hz

Indian Institute of Technology Bombay MATERIALS  MANAGEMENT  DIVISION

 Direct : (+91­22) 2576 8800 (DR) / 8803 (Local) / 8804 (Import) /  8805  (Enquiry & Bill tracking), 8802(Progress)  Email : [email protected][email protected] 

12. System Software: System software to configure the controller, interface to test station, to define, save and execute test procedure, access to test information from any web-enabled, internet-connected device, etc. Detail specification with its application features to be provided.

4

Application Software

Requirement: Multipurpose test suite to graphically build and run monotonic and cyclic test, acquisition of data, generation of signal (sine, haversine, square, triangle, random, earthquake time history development and generation, etc.), trigger, data export, report generation, etc. Details of software and its features to be provided.

Indian Institute of Technology Bombay MATERIALS  MANAGEMENT  DIVISION

 Direct : (+91­22) 2576 8800 (DR) / 8803 (Local) / 8804 (Import) /  8805  (Enquiry & Bill tracking), 8802(Progress)  Email : [email protected][email protected] 

ANNEXURE-2 Specifications for Static and Dynamic Structural Testing System S No. 1

Additional Requirements and Terms of Conditions Particulars Technical Requirement System Performance A Servo-hydraulic system comprising of: Requirement 1. +/- 500kN actuator with travel +/- 125mm (2 Nos.) 2. 56lpm or better Moog Servo Valve (2 Nos. on each actuator) 3. 200-300 lpm Hydraulic Power Unit (1 No.) should meet the following performance (minimum or better): 1. 400kN, 00.1 Hz Frequency, +/- 120mm 2. 400kN, 01.0 Hz Frequency, +/- 20mm 3. 400kN, 10.0 Hz Frequency, +/- 2mm Overall system performance curve to be provided with the details of each component in the system.

2

3

Installation and Commissioning

The vendor should take full responsibility for supply, installation and commissioning of the structural testing system in Heavy Structures Laboratory of Civil Engineering Department and performance of the system demonstrated to the satisfaction of the users. Necessary fittings and fixtures required for the installation of structural testing system to the reaction frame will be in the scope of the vendor. Maintenance and service support 1. The vendor should have competent and of system during and after the reliable service network in India for quick and warranty period necessary repair and maintenance of the equipment. 2. The vendor should provide the list of users of similar equipment (viz. IITs, NITs, etc.) along with their contact details. 3. Details of the nature of service support the vendor can provide should be given along with the proposal.

Indian Institute of Technology Bombay MATERIALS  MANAGEMENT  DIVISION

 Direct : (+91­22) 2576 8800 (DR) / 8803 (Local) / 8804 (Import) /  8805  (Enquiry & Bill tracking), 8802(Progress)  Email : [email protected][email protected] 

4

Terms and Conditions

4. Warranty should be for at least three years (3 years) after installation. 5. The vendor should commit to provide maintenance service and supply necessary spares for the equipment for at least 15 years after successful installation and commissioning. 1. Two sets of operation and maintenance manuals along with all necessary drawings should be supplied along with the structural testing system. 2. The vendor should enclose all the relevant technical documents and catalogues for all the components included in the proposal. Proposals without proper technical documents and catalogues will be rejected. 3. The vendor should impart training to the user viz. faculty, staff, student and any other personnel nominated by the department of civil engineering. 4. The parties may visit the Heavy Structures Laboratory of Civil Engineering Department to understand the test set-up (length of hoses, cables, additional fixtures for mounting of actuators and load cells, etc.) 5. Necessary consumables like connecting cables, power pack oil, hoses, etc. will be in the vendor’s scope. 6. Additional equipment like Cooling tower, UPS, Suitable PC with compatible operating system, etc. will be in the vendor’s scope. 7. IIT may provide the following: a. Electrical power required for the installation of structural testing system. b. An enclosure to cooling tower. c. Extend the workshop facility (without man power), if required for mechanical works like cutting, welding, drilling, etc. during the installation and

Indian Institute of Technology Bombay MATERIALS  MANAGEMENT  DIVISION

 Direct : (+91­22) 2576 8800 (DR) / 8803 (Local) / 8804 (Import) /  8805  (Enquiry & Bill tracking), 8802(Progress)  Email : [email protected][email protected] 

commissioning system.