Technical Specifications: CT-NET - Multi-Contact

7 downloads 32 Views 741KB Size Report
Mar 31, 2010 ... Attenuation characteristics CT-NET. NEXT in new condition: poles 1,2 & 3,6; CAT 5: attenuation according to. EN 50173-1. Determined values ...
Technical Specifications: CT-NET Mechanical characteristics Number of mating cycles:

n ≥ 5000

Electrical values Description

Symbol

Value

Transmission resistance

Rcontact

1.6 mΩ

Current-carrying capacity

Icontact

1A

Insulation resistance

Rinsulation

≥ 500 MΩ

Rated voltage

U

50V

Comments The transmission resistance relates to a single contact. The current-carrying capacity relates to a single contact with cable cross section area of 0.15mm²/AWG24. The insulation resistance was measured from contact to contact and from contact to shield.

Attenuation characteristics CT-NET NEXT in new condition: poles 1,2 & 3,6; CAT 5:

attenuation according to EN 50173-1 Determined values

31.03.2010

Data_connectors_V4-CT-NET en.doc

Page 1 of 6

NEXT after 5000 mating cycles: poles 1,2 & 3,6; CAT 5:

attenuation according to EN 50173-1 Determined values

FEXT in new condition poles 1,2 & 3,6; CAT 5:

attenuation according to EN 50173-1 Determined values

31.03.2010

Data_connectors_V4-CT-NET en.doc

Page 2 of 6

FEXT after 5000 mating cycles: poles 1,2 & 3,6; CAT 5:

attenuation according to EN 50173-1 Determined values

RL in new condition poles 1,2; CAT 5:

attenuation according to EN 50173-1 Determined values

31.03.2010

Data_connectors_V4-CT-NET en.doc

Page 3 of 6

RL in new condition poles 3,6; CAT 5:

attenuation according to EN 50173-1 Determined values

RL after 5000 mating cycles: poles 1,2; CAT 5:

attenuation according to EN 50173-1 Determined values

31.03.2010

Data_connectors_V4-CT-NET en.doc

Page 4 of 6

RL after 5000 mating cycles: poles 3,6; CAT 5:

attenuation according to EN 50173-1 Determined values

IL in new condition poles 1,2 & 3,6; CAT 5: 0.45 0.4 0.35

IL [dB]

0.3 0.25

Kat 5 IL 12

0.2

IL 36

0.15 0.1 0.05 0

Freq. [MHz]

31.03.2010

Data_connectors_V4-CT-NET en.doc

Page 5 of 6

IL after 5000 mating cycles: poles 1,2 & 3,6; CAT 5: 0.45 0.4 0.35 0.3 Kat 5

IL [dB]

0.25

IL 12

0.2

IL 36

0.15 0.1 0.05 0 Freq. [MHz]

EMV tests Measurement of shielding quality in conformity with standards by ESD Test and Burst Test.. Burst Test: Voltage Pol. Freq. Dur. Per. t Operation* with Operation* with housing Severity [V] [kHz] [ms] [ms] [s] shield only via pin connected to shield pin level 260 +/5 15 300 60 OK OK 260 +/100 0,75 300 60 OK OK 1 500 +/5 15 300 60 OK OK 1 500 +/100 0,75 300 60 OK OK 2 1000 +/5 15 300 60 OK OK 2 1000 +/100 0,75 300 60 OK OK 3 1500 +/5 15 300 60 OK OK 3 1500 +/100 0,75 300 60 OK OK 4 2000 +/5 15 300 60 OK OK 4 2000 +/100 0,75 300 60 OK OK *Ethernet ping command Test passed with attainment of highest severity level (4) defined in EN 61000-4-4. ESD Test: Voltage Discharge Pole. t [s] Operation* with Operation* with housing Severity [kV] shield only via pin connected to shield pin level 1 2 Contact 1 OK OK 2 4 Contact 1 OK OK 3 6 Contact 1 OK OK 4 8 Contact 1 OK OK 1 2 Air 1 OK OK 2 4 Air 1 OK OK 3 8 Air 1 OK OK 4 15 Air 1 OK OK *Ethernet ping command Test passed, with attainment of highest severity level (4) defined in test. Shield attenuation: 31.03.2010

86dB Data_connectors_V4-CT-NET en.doc

Page 6 of 6