Research Article
Valve–pump parallel variable mode control for hydraulic speed regulation of high-power systems
Advances in Mechanical Engineering 2017, Vol. 9(10) 1–16 Ó The Author(s) 2017 DOI: 10.1177/1687814017727682 journals.sagepub.com/home/ade
Haigang Ding1,2, Jiyun Zhao1, Chao Cao2 and Liang Zhao2
Abstract Aiming to improve the low-speed stability and dynamic response while retaining high efficiency, a valve–pump parallel variable mode control for hydraulic speed regulation systems is proposed which establishes a flexible control mechanism using pump control and valve control. At the start and stop stages, the leaking valve control mode is applied to improve low-speed performance by increasing leakages controlled by a valve. At the constant-speed stage, the replenishing valve control mode is used to improve response to load disturbance. At other stages, the pump control mode is applied to make full use of its high efficiency. The three control modes could switch smoothly and the proposed control method could achieve good speed tracking while working efficiently. Keywords Valve–pump parallel control, variable mode control, hydraulic speed regulation systems, low-speed performance, rapid response, efficiency
Date received: 5 September 2016; accepted: 1 August 2017 Academic Editor: Muhammad Akhtar
Introduction A traditional hydraulic speed regulation system includes two basic types: pump control (PC) and valve control. The valve control system responds quickly to valve and load inputs, but it is less efficient because of inevitable throttling loss. So the valve control system is applicable for applications requiring rapid response with low power.1–3 The PC system is more efficient as it avoids the throttling loss, but responds slowly, so it is suitable to some applications requiring high power with a slow response.1,2,4–6 The valve–pump combination control, which gives full play to advantages of valve control and PC, will make a hydraulic system efficient and offer a rapid response.7 The combination of control modes has two types: series and parallel. In the valve–pump series control system, a control valve and a pump are connected in series to control the flow together. Manasek8 proposed a valve–pump series variable speed hydraulic system to accelerate the response of the PC, in which a flow control valve is installed, in series, in the main circuit.
An energy-regulating device is added to the above system and forms a variable speed hydraulic system based on energy regulation.9–11 The energy regulation device can absorb redundant energy during system deceleration, as well as release energy during system acceleration, so the dynamic response of this system can be increased. The flow control valve limits the maximum flow in the system, and therefore the above serial control systems are unfit for large flow systems operating at high power. In the valve–pump parallel control system, the flow control valve is mounted, in parallel, in the main circuit, 1
School of Mechatronic Engineering, China University of Mining and Technology (CUMT), Xuzhou, China 2 Jiangsu Key Laboratory of Mine Mechanical and Electrical Equipment, China University of Mining and Technology (CUMT), Xuzhou, China Corresponding author: Haigang Ding, School of Mechatronic Engineering, China University of Mining and Technology (CUMT), No. 1, Daxue Road, Xuzhou 221116, China. Email:
[email protected]
Creative Commons CC-BY: This article is distributed under the terms of the Creative Commons Attribution 4.0 License (http://www.creativecommons.org/licenses/by/4.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/ open-access-at-sage).
2 so the parallel control system is suitable to applications with large flow and high power. Recently, research into parallel control systems mainly focuses on electrohydraulic actuators (EHAs),12–14 which are positioning servos. These parallel control devices can only improve system response characteristics but exacerbate the problem of low-speed performance. Moreover, these parallel control systems have a drawback in principle: there are no replenishing arrangements in such compound systems which are closed cycle systems, and the authors try to control the actuator and replenish fluid in the system using only the valve control branch circuit. During the control process, the valve flow depends on control requirements and is usually variable, but the replenishing flow depends on load pressure and is usually comparatively constant, so the control valve cannot give consideration to both functions. There is another kind of valve–pump parallel control system called a paralleled valve control servo system, of which there are two types: a throttling system15,16 and a compensating system.17 The control valve is in its leaking status in the former and, on the contrary, in its replenishing status in the latter. Therefore, the latter has a higher stiffness. The parallel valve control system is a type of constant servo, in which the pump operates in fixed displacement status and supplies the majority of the required flow, and the bypass valve is used to realize a rapid response to load disturbance. In many engineering applications, some control systems requiring a lot of power (e.g. hydraulic winches) may undergo obvious speed regulation stages including start-up, acceleration, uniform, deceleration and stopping18 and require comprehensive properties, such as low-speed performance, rapid response to load variation and retention of their high efficiency. Valve–pump parallel control systems cannot meet all these requirements due to their fixed control mode.19 In this article, a new type of valve–pump parallel control system is presented, that is, the valve–pump parallel variable mode control system; its control modes can vary with control requirements during the regulation process. This article is organized as follows: system principles are presented in section ‘System principles’, system mathematical modelling is covered in section ‘Mathematical modelling’, dynamic performance analyses (such as lowspeed performance, rapid response) are discussed in section ‘Dynamic characteristic analysis’, valve-pump parallel variable mode control of whole regulation process is discussed in section ‘Variable mode control’, the parallel control system efficiency is qualitatively analyzed in section ‘Efficiency analysis’, and conclusions are drawn in section ‘Conclusion’.
System principles Figure 1 shows the hydraulic principle diagram of the proposed system. It is a closed cycle system and has an
Advances in Mechanical Engineering
Figure 1. Hydraulic principle diagram of the proposed system. 1, Variable mechanism; 2, variable pump; 3, PDV; 4, shuttle valve; 5, replenishing arrangement; 6, heat exchanger arrangement; 7, hydraulic motor; 8, inertia; 9, encoder; 10, loading pump; 11, proportional relief valve; 12, loading system; 13, oil source for the PDV.
Figure 2. Speed regulation process in a duty cycle. 1, Start; 2, acceleration; 3, uniform; 4, deceleration; 5, stop.
individual replenishing arrangement to supplement system leakages and maintain the pressure stability of the low-pressure chamber. The heat exchanger is used to exchange hot fluid from the return chamber and balance system flow. The proportional directional valve (PDV) is connected to high-pressure chamber through a shuttle valve to drive the hydraulic motor with the pump and could work in both replenishing status and leaking status according to control signals received. The load pressure of the loading system is controlled by the proportional relief valve. The speed of the hydraulic motor is measured and fed back to the controller via the encoder, and the controller outputs two control signals: one to the PDV to regulate its opening and another to the pump to change the pump speed. Figure 2 shows the principle in a duty cycle: 1.
Under the leaking valve control (LVC) mode at the start and stop stages. During the two stages, the variable pump works as a fixed pump and discharges a certain amount of fluid flow, which is equal to the system flow producing a stable speed in the hydraulic motor. The PDV, with a pre-opening, is given negative currents to form a bypass leakage passage and improve the lowspeed performance of hydraulic motor. At the start-up stage, the valve opening gradually closed, and the motor speed gradually increased, and vice versa at shut-down.
Ding et al. 2.
3.
Under variable PC (VPC) mode at the accelerating and decelerating stages. The PDV is closed with zero voltage, and the motor speed varies with pump displacement. Under the replenishing valve control (RVC) mode at the uniform stage. The pump maintains a fixed displacement and supplies a certain fluid flow, which is less than the flow required at the desired motor speed, and the valve is given a positive current to provide compensatory fluid flow to the forward chamber and improve the dynamic response to load disturbance.
Therefore, the ‘variable mode control’ means that system control modes could vary with regulation requirements, which can make full use of advantages of PC and valve control to allow low-speed stability and fast response while retaining its high efficiency.
Mathematical modelling Although such a hydraulic system is typically non-linear, the proposed system is described in linear form because of the following: (1) currently, the theory and analysis of non-linear system are undeveloped and immature, so some non-linear equations, especially those which describe the pressure–flow curves of hydraulic control valves, should be linearized under special conditions. (2) Even if non-linear solutions are easily obtained, all of them would not be ill-suited because design procedures and performance specifications are based on linear theory. (3) The proposed system, made up of PC, valve control and valve–pump compound control, is new and complicated and is difficult to express using non-linear equations; however, we can learn much from the linearized theory of PC and valve control which are comparatively mature and justified and find relevant knowledge in Merritt1 and Manring.2 Therefore, linearized analysis is essential to, and suitable for, this work. To linearize the system, the linearization point should be clear and definite because coefficients of the linearized equations, such as the valve coefficients, flow gain and flow–pressure gain, vary with operating point. The most important operating point is at neutral (where Qv = DP = xv = 0) because system operation usually occurs near this region, where the valve flow gain is largest (thus giving maximum system gain), and the flow–pressure gain is minimized (thus giving a low damping ratio). Therefore, linearized analysis is usually undertaken at the null operating point because it is the most critical from a stability perspective, and a system that is stable at this point is usually stable at all operating points. In addition, this has been done for mathematical expediency because the differential equations
3
Figure 3. Schematic of the variable mechanism.
are highly non-linear, and from those no simple, or useful, results can be obtained. In fact, the linearized analysis usually conforms with physical facts to a substantial degree, although the valve and system coefficients, such as damping ratios, vary with operating point. This analysis helps relieve our anxiety about the usefulness of linearized analysis and increase our confidence in any design based on such analysis.
Variable pump link Figure 3 shows the variable mechanism of a variable pump. The mechanism consists of a piston, a position sensor, a servo valve and a proportional–integral–derivative (PID) controller, used as a positioning servo system.18,20,21 As suggested elsewhere,18 the positioning servo system could be simplified as a first-order inertia link, that is xp 1=Kf = s up vbp + 1
ð1Þ
where up is the input voltage, xp is the piston position, Kf is the feedback gain of sensor and vbp is the break frequency. The unload flow of the variable pump can be approximated by Qp0 =
Kdp =Kf up = s vbp + 1
Kv2 up +1
s vbp
ð2Þ
where Kdp is the gain of the position–unload flow and Kv2 is the gain of the input voltage–unload flow. Hence, the actual flow of variable pump is Qp = Qp0 Ctp Ph
ð3Þ
where Ctp is the total leakage coefficient of the pump and Ph is the output pressure thereof.
Valve control link The parallel control valve PDV is a critical centre spool valve and is matched symmetrically. Its orifice equation is given by
4
Advances in Mechanical Engineering sffiffiffiffiffiffiffiffiffi 2DP Qv = Cd wxv r
ð4Þ
where Cd is the discharge coefficient, w is the area gradient, xv is the valve displacement, r is the density of the fluid and DP is the pressure drop across the valve. xv as a function of the control input Iv is xv = Kd Iv
ð5Þ
where Kd is the gain in the valve dynamics. Hence, the orifice equation of the valve can be expressed as pffiffiffiffiffiffiffi Qv = Csv Iv DP
where Qvr, Kqr, Kcr and Ivr are the flow, flow gain, flow– pressure gain and control input of the PDV at replenishing status, respectively. Considering the PDV as a second-order oscillating link, its unload flow at leaking status Ql0 is given by
ð6Þ
is the valve constant and where Csv Csv = Cd wKd (2=r)1=2 . Using a Taylor series, the linearized orifice equations are written as 8 Qv = Kq Iv + Kc DP > > > > pffiffiffiffiffiffiffi > ∂Qv < = Csv DP Kq = ∂Iv > > > ∂Q Csv Iv > v > = pffiffiffiffiffiffiffi : Kc = ∂DP 2 DP
Hence, the linearized flow equation of the valve in its replenishing status is 8 Qv r = Kqr Ivr Kcr Ph > > > pffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi < Kqr = Csv Ps Ph ð12Þ > > Csv Ivr > : Kcr = pffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi 2 Ps Ph
Ql0 =
Qr0 =
where Kq is the flow gain of the PDV, and Kc is the flow–pressure gain of the PDV. Under LVC mode, the PDV works in its leaking status, and the pressure drop DP is
Hydraulic motor link
ð8Þ
s vsv 2
Kql Ivl 2j + sv s + 1 vsv
ð13Þ
where vsv and jsv are the hydraulic natural frequency and damping ratio of the PDV, respectively. Its unload flow Qr0 at replenishing status is given by
ð7Þ
DP = Ph 0 = Ph
2
Kqr Ivr s2 2j + sv s + 1 2 vsv vsv
ð14Þ
Under LVC mode, the total system continuity equation is Qp Qvl = Cm Ph + Dm v + V0 sPh =be
ð15Þ
Under RVC mode, the total system continuity equation is
So the linearized flow equation of the valve in its leaking status is
Qp + Qvr = Cm Ph + Dm v + V0 sPh =be
8 Qv l = Kql Ivl + Kcl Ph > > > pffiffiffiffiffi < Kql = Csv Ph > > Csv Ivl > : Kcl = p ffiffiffiffiffi 2 Ph
where Cm, v, and Dm are the leakage coefficient, angular speed and displacement of the hydraulic motor, respectively, and V0 is the average volume of the forward chamber. The torque balance equation for the hydraulic motor is
ð9Þ
where Qvl, Kql, Kcl and Ivl are the flow, flow gain, flow– pressure gain and control input of PDV when leaking, respectively. Under RVC mode, the valve works in its replenishing status, and the pressure drop DP is DP = Ps Ph
ð10Þ
where Ps is the supply pressure of the PDV, and its linearized flow equation is Qv = Kq Iv + Kc (Ps Ph )
ð11Þ
KcPs is constant and should be omitted because the linearized flow equation is an incremental equation.
Dm Ph = Jsv + Bm v + TL
ð16Þ
ð17Þ
where J is the equivalent total inertia and Bm is the vicious damping coefficient. TL = DL Ph is the load torque produced by the loading pump, ignoring any lowpressure chamber pressure, and DL = Dm is the loading pump displacement. Combining equations (3), (9), (13), (15) and (17), the open-loop dynamic equation of the parallel control system under LVC mode is given by Qp0 Ql0 Cl s TL 2 1+ Dm 2vl jl Dm v= s2 2j + l s+1 2 vl vl
ð18Þ
Ding et al.
5
Figure 4. Block diagram of the proposed system. Note: subscript m/x represents m or x, and x represents r and l, respectively.
pffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi where Cl = Cp + Cm + Kcl , ffi vl = (be Dm 2 )=(V0 J ) and pffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi jl = (Cl )=(2Dm ) (be J )=(V0 ) are the total leakage coefficient, natural frequency and damping ratio of the system under LVC mode, respectively. Combining equations (3), (12), (14), (16) and (17), the open-loop dynamic equation of the parallel control system under RVC mode is Qp0 + Qr0 Cr s 2 1+ TL Dm 2vr jr Dm ð19Þ v= s2 2jr + s+1 vr 2 vr pffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi (be Dm 2 )=(V0 J ) and where Cr = Cp + m + Kcr , ffi vr = pC ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi jr = (Cr )=(2Dm ) (be J )=(V0 ) are total leakage coefficient, natural frequency and damping ratio of the system under RVC mode, respectively. When the PDV is closed, the LVC mode and RVC mode will switch to VPC mode,2,6 and its open-loop dynamic equation is Qp0 Ct s TL 2 1+ D 2vm jm Dm ð20Þ v= m s2 2jm + s+1 vm 2 vm pffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi +ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi Cm , vmffi = (be Dm 2 )=(V0 J ) and where Ct = Cpp jm = (Ct )=(2Dm ) (be J )=(V0 ) are the total leakage coefficient, damping ratio and hydraulic natural frequency under VPC mode, respectively. The rotary part is simplified as a proportional element due to its fast response, and Km =
um nm
ð21Þ
where um is the feedback voltage, Km is the feedback gain and nm = 60wm/(2p) is the motor’s rotational speed.
Table 1. System parameters. Symbol
Value
Unit
V0 J Dm Ct Km vsv jsv vm jm Kql or Kqr Cl or Cr vl or vr jl or jr K1 K2 K3
1.0 3 1023 70 7.45 3 1025 2.94 3 10212 1/6 250 0.7 10.48 0.19 8.6 3 1026 2.94 3 10212 10.48 0.19 2.14 3.10 3.10
m3 kg m2 m3 =rad m3 (s Pa) V min=r rad=s rad=s m3 =(s mA) m3 =(s Pa) rad=s
Total system mathematical model Figure 4 shows the control block diagram of the parallel control system, which is made up of a valve control link, a variable pump link and a hydraulic motor link. The system parameters are listed in Table 1. The parameters Dm, V0 and J are set according to the actual product. The total leakage coefficient, natural frequency and damping ratio under the three different control modes are calculated by formulas in equations (18)–(20). The compensated open-loop gains under three different control modes, K1, K2 and K3, are determined by formulas in equations (28)–(30) and stability criterions: K vj. The uncompensated open-loop transfer functions of the proposed system under VPC mode, LVC mode and RVC mode are, respectively, given by
6
Advances in Mechanical Engineering
Gmk (s) =
Glk (s) =
60Km Kv2 =(2pDm ) 2 s s 2jm +1 + s+1 vm 2 vm vbp
ð22Þ
60Km Kql =(2pDm ) 2 ð23Þ s 2jm s 2jsv + s+1 + s+1 vm 2 vm vsv 2 vsv 2
60Km Kqr =(2pDm ) 2 ð24Þ s2 2jm s 2jsv + s+1 + s+1 vm 2 vm vsv 2 vsv
Grk (s) =
These velocity servo loops are of Type 0 and offer poor performance (with regard to stability) due to their low phase margin, especially for the usual case of a low damping ratio jm according to the bode diagrams of Type 0 servos plotted elsewhere.1 So these velocity servo loops should be compensated for stability with an adequate phase margin. The simplest method is to add integral links to these loops. Then, these corrected loops become Type 1 loops, and the compensated open-loop transfer functions of the parallel control system under the three control modes are, respectively, given by K1 2 Gmk (s) = s s 2jm s +1 + s + 1 vm 2 vm vbp Glk (s) = 2 s 2z s + l s+1 vl 2 vl
K2
2 TL = K1 Dm n Ct m m 2 TL = K 2 Dm n Cl m l 2 TL = K 3 Dm n Cr m r
ð25Þ
ð28Þ ð29Þ ð30Þ
Dynamic characteristic analysis
s2 2jsv + s+1 vsv 2 vsv ð26Þ
K3 2 ð27Þ Grk (s) = 2 s 2zr s 2jsv s + s+1 + s+1 vr 2 vr vsv 2 vsv where KmI , KlI and KrI are the integral gains; K1 = 60KmI Kv2 Km =(2pDm ), K2 = 60KlI Kql Km =(2pDm ) and K3 = 60KrI Kqr Km =(2pDm ) are the compensated
Figure 5. Simulation model as run on AMESim.
open-loop gains of the proposed system under VPC mode, LVC mode and RVC mode, respectively. From Table 1, vm = vl = vr \vbp vsv , so the hydraulic natural frequency vm (or vl or vr ) is the lowest break frequency and dominates dynamic performance of the total system. So vsv in equations from (25) to (27) can be omitted. According to the stability criterion, and to get the appropriate amplitude and phase margin, these compensated open-loop gains should satisfy the following relationships: K1 vm jm , K2 vl jl and K3 vr jr . We set KmI = 1:5, KlI = 1:5 and KrI = 15 (at Ps = 2Ph ) noting that values of KlI and KrI are estimated conservatively, because the damping ratio varies widely. The static closed-loop speed stiffness under VPC mode, LVC mode and RVC mode are, respectively, given by
Simulation model Figure 5 shows the simulation model of valve–pump parallel control as run on AMESim, a professional multidisciplinary simulation software suite, is widely applied in hydraulic, automation and so on.22 In general, an AMESim simulation needs four steps: sketch . sub-models . parameters . simulation. The key components of AMESim are listed in Table 2. FP04 is used to set the characteristics of the hydraulic fluid, in which the effective bulk modulus is 1400 MPa. To simulate the total leakages of pump and
Ding et al.
7
Table 2. Key components of the AMESim platform. Component
Specification
Variable pump PDV
A4VSG40HS; max. displacement: 40 mL/r; rotary speed: 1000 r/min; control devices: HS Max. flow at 1.5 MPa per notch: 9 L/min; max. current: 40 mA; frequency: 40 Hz; damping ratio: 0.7 Speed range: 0–90 r/min; displacement: 468 mL/r; rated pressure: 40 MPa Pressure range: 0.7–31.5 MPa; max. flow: 200 L/min 70 kg m2
Hydraulic motor and loading pump Proportional relief valve Rotary inertia PDV: proportional directional valve.
motor Ct, a fixed orifice is installed into two chambers of the hydraulic motor and is set to 1 L/(min MPa). The rated voltage of variable pump is set to 10 V corresponding to its maximum displacement. The rated input of the PDV is 40 and 240 mA corresponding to maximum positive and negative opening, respectively. Many types of loads, such as sinusoidal load, ramp load, step load and square load, are applied to the system by feeding different inputs to the proportional relief valve. A controller is built, which could switch between VPC, LVC and RVC modes.
Low-speed performance analysis Theoretical basis. The factors influencing the low-speed stability of hydraulic motors mainly include external factors (flow and pressure ripple of oil source, load disturbance) and integral factors (friction torque, motor displacement ripple, leakages). However, the friction torque is the principal factor.23,24 Friction is a complex non-linear physical phenomenon and can be approximately described by static models or dynamic models.25– 27 Figure 6 and equation (30) show a normal static model for friction torque, which takes Coulomb friction, stiction and viscous friction into account. The Stribeck effect is described by the third item of equation (31) 8 < Te Tf = Ts sgn(n) 2 : Tc + (Ts Tc )e(n=ns ) + Tv n
Figure 6. A normal static friction model with Stribeck effect.
4b Kce J B. Bm + e V0
where B = dTf =dn is the damping coefficient of friction torque, Kce is a system total leaking coefficient and other parameters are defined as before. In the low-speed region, because of the Stribeck effect, the slope between friction torque and speed is
if n = 0 and jTe j\Ts if n = 0 and jTe j Ts other
where Te , Ts and Tc are external torque, static torque and Coulomb friction torque, respectively; n and ns are the relative speed and Stribeck speed, respectively; Tn is the viscous friction coefficient and sgn(n) is the sgn function. The Stribeck effect is often used to describe the friction behaviour of low-speed regions, that is, friction torque decreases as speed increases when jnj\ns . The Stribeck effect affects the low-speed stability of motors. Some previous studies28–30 give the necessary condition for low-speed stability, as
ð32Þ
ð31Þ
negative, that is, B\0. Bm is usually small and could be ignored, so low-speed stability will be improved by increasing the system total leakage coefficient Kce and inertia J. In Figure 6, ns is a critical speed, and the actual motor speed will oscillate below that speed, but the oscillation will disappear above it: this is called the stick–slip phenomenon, and ns is given by28,31,32 Ts Tc ns = pffiffiffiffiffiffiffiffiffiffiffiffiffiffi 4pjKJ
ð33Þ
8
Advances in Mechanical Engineering
where K is the system stiffness and j is the system damping ratio, so a lower critical speed will be obtained by increasing K, J and j. In addition, j can be given by33 1 j= 4
sffiffiffiffiffiffiffiffiffiffiffi V0 J B + Bm 4Kce be + J V0 be Dm
ð34Þ
Therefore, increasing Kce will increase j and lead to a lower critical speed ns. Research shows that the negative value of B becomes larger and j becomes smaller while the speed decreases in the low-speed region, which is more likely to cause low-speed instability.34 In addition, the phenomena of flow and pressure ripple are inherent to a piston-type variable displacement.35 Moreover, its variable mechanism usually oscillates with a small displacement due to friction and the dead band of PDV, which will aggravate the flow, pressure ripple in the oil source and low-speed instability of the motor. Based on the above analyses, LVC is applied to lowspeed stages, which has the following advantages: 1.
2.
3.
Pump displacement could work within a stable region, which will make the flow of oil more stable and avoid using variable displacement pumps for good low-speed stability. Increased damping ratios and total leaking coefficients will result in a lower critical speed and improve low-speed stability. The variation in damping ratios due to valve control is contrary to that of the damping ratios in the low-speed region, which could compensate for the reduction in damping ratios because of the friction’s decreasing trend, thus helping to improve lower critical speeds.
Verification by simulation. To avoid the instability due to closed-loop control, this simulation is carried out in open-loop control. The friction model with Stribeck effect is applied to simulations, and the parameters are as follows: Ts = 600 N m, Tc = 400 N m, Tv = 0 and ns = 10 r/min. Figure 7 indicates the influences of the Stribeck effect on friction torque and motor speed in PC mode. It shows that the transition from static torque to Coulomb friction torque is exponential, not instantaneous, after adding the Stribeck effect, which causes motor speed instability. The simulation results prove that the friction model, with the Stribeck effect, could simulate the actual friction in motor. Figure 7(b) also indicates that the motor cannot offer a good low-speed performance in single PC mode. Figure 8 shows the influences of different valve preopenings on start performances under LVC mode.
Figure 7. Influences of the Stribeck effect on friction torque and motor speed in pump control mode ( J = 70 kg m2): (a) friction torque and (b) motor speed.
Figure 8(a) indicates control inputs of the PDV and pump. Keeping the pump inputs constant (up = 2 V corresponding to QP = 8 L/min), the valve inputs, respectively, change from 210, 220, 230 mA, to 0 mA, corresponding to valve pre-opening decreases from 25%, 50%, 75%, to 0%, respectively. The red curve (0% pre-opening) is the pump input in only PC. Figure 8(b) and (c) indicates that under LVC mode, total leakage coefficient and damping ratios become large and increase with valve inputs and reach a maximum when the motor starts to move, but under PC mode, the parameters are small and constant and are barely affected by the pump inputs. The reasons for this are as follows: comparing equations (18) and (20), the total leakage coefficient under LVC mode, Cl = Ct + Kcl, increases by introducing the valve flow–pressure coefficient Kcl, for valve control. Ct is usually small and constant, but Kcl is much greater than Ct and changes widely pffiffiffiffiffi with valve input Ivl according to Kcl = (Csv Ivl )=(2 Ph ). Figure 8(d) shows that, compared with PC, LVC could negate the influences of the Stribeck effect and provide good low-speed stability; moreover, the start time and acceleration when controlling the valve pre-opening result therefrom. According to equations (32)–(34), the low-speed performance could be improved by increasing J, which is verified in Figure 9; however, increasing inertia will
Ding et al.
9
Figure 8. System response under LVC mode: (a) inputs of valve and pump, (b) total leakage coefficient, (c) damping ratios and (d) motor speed.
Figure 10. Low-speed performance of the motor in closedloop control.
Figure 9. Influence of inertia on damping ratios and motor speed in pump control: (a) damping ratios and (b) motor speed.
reduce the system natural frequency and response speed, will require more space and will increase the weight and cost of the system. Therefore, increasing leakage by LVC is more economical and flexible than increasing system inertia. Similar performances will be obtained when applying LVC to the stop stage. Stability in open-loop control is conducive to stability in closed-loop control, so, as shown in Figure 10, compared with the system under PC mode, that under LVC mode could achieve good tracking and low-speed performance in closed-loop control.
10
Advances in Mechanical Engineering
Figure 11. Total leakage coefficients under variable loads: (a) Ct under different modes, (b) under LVC mode and (c) under RVC mode.
Rapid response performance analysis According to section ‘System principles’, RVC is used to obtain a rapid response to load disturbance in the constant-speed stage. In fact, LVC is also variable after the start stage, which means that the valve cannot be closed totally and should be kept open by a certain amount in the constant-speed stage to obtain a rapid response by controlling leakage. In this section, RVC is compared with PC and LVC. In the constant-speed stage, the motor speed is high, so the Stribeck effect is ineffective and can be omitted.
Influences of load variation on system parameters. First, we discuss the influence of load pressure on system parameters, such as total leakage coefficient, damping ratios and speed stiffness. This part is discussed in open-loop control mode terms. Figure 11 shows the effects of load variation on total leakage coefficient. The load is produced by the proportional relief valve and is similar to square waves and varies between 6 and 10 MPa. Figure 11(a) shows that compared with Ct under VPC mode, those under RVC and LVC mode are similar to square waves. Compared with Cl in Figure 11(b), Cr in Figure 11(c) is more stable, so the system under RVC mode has comparatively stable total leakage
coefficients. We can find the reason from the exprespffiffiffiffiffi sions for Ct, Kclpffiffiffiffiffi and Kcr, that is, Ct = (Qpmp)=(2 Phffi), ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi Kcl = (Csv Ivl )=(2 Ph ) and Kcr = (Csv Ivr )=(2 Ps Ph ). Ct and Kcl vary inversely with Ph and have the same variation tendency, and Cl = Ct + Kcl, so Cl undergoes greater variation under variable loads in LVC mode; Kcr is proportional to Ph, so Ct and Kcr have contrary variation tendencies, and Cr = Ct + Kcr; therefore, Cr undergoes less variation under variable loads under RVC mode. The influence of total leakage coefficient variation caused by variable loads under different modes has two facets: For damping ratio, the damping ratio is proportional to total leakage coefficient, and Figure 12(a) shows that for the same valve opening, damping ratios in LVC and RVC are greater than that in VPC, but damping ratios in RVC are more stable than that in LVC and VPC modes. Therefore, the system in RVC mode has more stable parameters, which helps parameter prediction and system control. For speed stiffness, speed stiffness vary inversely with total leakage coefficient, and Figure 12(b) shows that motor speeds in LVC and RVC are more similar to square waves compared with that in VPC,
Ding et al.
11 which implies that the system in valve–pump parallel control has lower speed stiffness and is more sensitive to load variation because of the increased leakage. Although regular trends are obtained (see above) in open-loop control, they are still variable under closedloop control.
Rapid response performance analysis. This part is discussed in closed-loop control mode terms. As discussed in section ‘Total system mathematical model’, the three control loops are corrected by integral links, and the gains are set to KmI = 1.5, KlI = 25 and KrI = 25, respectively. The pre-opening current is 15 mA under LVC mode: 1.
Figure 12. Damping ratio and motor speed response under variable loads: (a) damping ratios and (b) motor speed.
For the same step load, the speed drop in RVC is smaller than that in LVC and larger than that in VPC, which shows that speed stiffness in RVC is greater than that in LVC and lower than that in VPC. That is because the speed stiffness is inversely proportional to the total leakage coefficients according to equations (28)–(30), and Ct \ Cr \ Cl as shown in Figure 13(b).
Figure 13. Response for step loads: (a) motor speed, (b) total leakage coefficient and (c) damping ratio.
12
Advances in Mechanical Engineering increasing Ps will reduce Kcr and Cr. According to equation (30), increasing K3 and reducing Cr will enhance speed stiffness.
Figure 14. Motor speed response for step load under different values of Ps.
2.
3.
System parameters in RVC are more stable than those in LVC. Figure 13(b) and (c) shows that total leakage coefficients and damping ratios in LVC change widely, for example, the damping ratio changes from 1.6 to 0.5, but these parameters are comparatively constant in RVC, for example, the damping ratio is about 0.5. Compared with PC, valve–pump parallel control responses to load variation are rapid because, first, systems under the chosen three control modes have the same natural frequency, that is, vm = vl = vr , as discussed in section ‘Simulation model’. Second, the control valve has a higher response speed than the variable pump.
Figure 13 shows the step response in the three control modes, and we find that the system in RVC mode response is less susceptible to load variation compared with that in LVC. As shown in Figure 13(a), the system in LVC responds rapidly at high load pressure (e.g. at t = 10 s) and slowly at low load pressure (e.g. at t = 6 s), which is even slower than that in VPC.pThe ffiffiffiffiffi reason is as follows: according to Kcl = (Csv Ivl )=(2 Ph ), Kcl is inversely proportional to Ph, which means a smaller Ph produces a greater Kcl, Cl and jl . As shown in Figure 13(c), jl exceeds 1 at 6 s, which decelerates the response and prolongs the settling time, but the damping ratio in RVC mode remains at about 0.5 throughout, which contributes to faster response. The system under RVC mode could provide two benefits by raising the supply pressure Ps of the control valve as shown in Figure 14: 1.
2.
Accelerating response. According to flow gain pffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi ffi Kqr = Csv Ps Ph and equation (27), increasing Ps will increase Kqr and open-loop gain K3 and accelerate the system response. Improving speed stiffness. Accordingpto flow– ffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi ffi pressure coefficient Kcr = (Csv Ivr )=(2 Ps Ph ),
However, the system in LVC mode does not have such flexibility, because, when the control valve pffiffiffiffiffiworks in its leaking status, its flow gain Kql = C sv pffiffiffiffiffi Ph and flow–pressure coefficient Kcl = (Csv Ivl )=(2 Ph ) are only related to load pressure Ph not Ps, and Ph varies with load and cannot be artificially controlled. Furthermore, for the same valve opening, Kqr . Kql and K3 . K2 when Ps . 2Ph, so the system under RVC mode will respond faster with higher closed stiffness than the system under LVC mode.
Variable mode control Now valve–pump parallel variable mode control is applied to the whole regulation process based on the above analyses. As shown in Figure 6, the system is loaded by a loading pump and a friction model described by equation (31), with Ps set to 15 MPa, and step disturbances at 20 and 28 s. The variable mode controller is developed and could change control modes according to the reference speed n (n = um/Km, nmax = 54 r/min). When 0 n 12, LVC mode is used; when 52 n 54, RVC mode is adopted; otherwise, VPC mode is used. The whole regulation process is carried out under closed-loop control. The switch points are set by the following rules: the switch point at low speed should be set to the minimum stable speed obtained in single PC, and the pump’s initial displacement is determined by the sum of this flow corresponding to this speed and any leakage from pump and motor. Meanwhile, the valve pre-opening should be set to leak the flow corresponding to this speed in its entirety. Therefore, according to the simulation results in section ‘Low-speed performance analysis’, this speed is set to 12 r/min, the initial voltage of the pump is 2 V, the flow corresponding to that speed is 8 L/min and the initial current through the PDV is 213 mA corresponding to 32.5% valve opening. The switch point for high-speed operation is slightly less than nmax and is set to 52 r/min. Figure 15 shows the dynamic response of the system in valve–pump parallel variable mode control and in single PC in a duty cycle. Figure 15(a) indicates that compared with PC, the valve–pump parallel control achieves good low-speed stability by LVC at start and stop stages and rapid response to load variation by RVC throughout the constant-speed stage. Moreover, the valve–pump parallel control system achieves good speed-tracing accuracy in the overall regulating process and switches smoothly between the three modes.
Ding et al.
13
Figure 15. System responses in a duty cycle: (a) motor speed, (b) speed error, (c) damping ratios and (d) system pressure.
Figure 15(b) shows that the speed error in variable mode control is smaller than that in PC in the above three stages. Figure 15(c) shows that the damping ratios in variable mode control are more stable and are also greater: they increase as the speed decreases at the start and stop stages which matches earlier supposition. Figure 15(d) shows the system in variable mode control to undergo a smaller pressure shock especially in the low-speed stage. As shown in Figure 16, during the closed-loop control process, trends of the changes in the valve and pump meet expectations, and the corresponding flows in the pump and valve are continuous and without mutation.
Efficiency analysis After addressing concerns about system dynamic response in variable mode control, we now analyse the system efficiency. The power of hydraulic systems is the product of pressure and flow, and pressure varies with loads, so the control of energy is essentially the control of flow, which could be controlled artificially. In the valve–pump parallel control system, the system flow, ignoring system leakages, is given by Qs = Qp + Qv
ð35Þ
Figure 16. Valve and pump responses in a duty cycle: (a) control signals of valve and pump and (b) valve flow and pump flow.
14
Advances in Mechanical Engineering
where Qs is the system flow and also the input flow to the hydraulic motor, Qs = Qp + Qv under RVC mode and Qs = Qp 2 Qv under LVC mode. There are two basic control modes in this parallel control system: PC and valve control. PC is more efficient because both flow and pressure are closely matched with the load requirement and this is accompanied by near-zero throttling loss. However, valve control is less efficient because of the unavoidable throttling loss. Therefore, the system energy loss is mainly generated in valve control mode, so the system efficiency h is 8 Nm > > h= > > N + Nm v > < Nv = Dp 3 Qv > > > N m = Qs 3 P L > > : Kpv = Qp =Qv
ð36Þ
where Nm is the output power of the hydraulic motor; PL is the load pressure; Nv is the throttling loss due to valve control, which increases with valve flow; Dp is the pressure drop at the valve orifice and Kpv is the flow ratio of pump to valve. Combining equations (35) and (36), the expression for system efficiency under LVC and RVC modes is h=
(Kpv 6 1)PL DP + (Kpv 6 1)PL
ð37Þ
In equation (37), ‘ + ’ denotes RVC mode, and ‘2’ denotes LVC mode. In fact, in this pump–valve parallel control system, the pump provides the majority of the flow and the valve only supplies a little. So Qp Qv , and then Kpv 1. Therefore, equation (37) can be simplified to Kpv PL h= DP + Kpv PL
As discussed in section ‘Variable mode control’, modes switch according to speed, so the switch points exert a significant influence on system efficiency. In the start and stop stages, the PDV works in its leaking status and system flow leaks from the valve, so energy loss arises mainly from the valve throttling loss. The higher the switching speed, the more flow leaks and the more energy the system loses. In the uniform stage, the valve works in its replenishing status and the energy loss mainly includes overflow losses and throttling loss. If the switch speed at this stage is too low, the throttling loss will increase. On the other hand, to reduce the overflow loss, a pump with high pressure and low flow characteristics should be selected to supply fluid to the valve, because only a small amount of fluid will flow through the valve at this stage anyway. If conditions allow, the various pump with constant pressure control36 may be used to improve system efficiency further, and the pump can provide constant pressure and matched flow without overflow loss. This article mainly studies the influence of valve control on the low-speed stability and dynamic response, and efficiency of the valve–pump parallel control system. In the combined control system, valve control plays only a supporting role, because the pump supplies most of the flow and the valve handles very low flows. Therefore, we only made a comparison between the valve–pump parallel control and PC in this study. We can make a preliminary comparison between the valve– pump parallel control and valve control: only the system in valve control could be characterized with good low-speed stability and rapid dynamic response, but with low efficiency due to the throttle lose result from valve control.
Conclusion ð38Þ
Therefore, we obtain a unified efficiency expression for a valve–pump parallel variable mode control system, and we can draw the following conclusion: the ratio Kpv could be used to describe the system efficiency, and the greater the Kpv, the higher the system efficiency. Figure 16(b) shows that most of the required flow is supplied by the pump and the valve only provides, or leaks, a small amount of flow throughout the process. So the valve–pump parallel control system offers a high efficiency while achieving a sound dynamic performance overall. In addition, if the maximum speed increases, Kpv will be greater and the proposed system will be more efficient. That is because the majority of the flow corresponding to its maximum speed is supplied by the pump not the valve.
This article presents a valve–pump parallel system with variable mode control, and the following conclusions were obtained: 1.
2.
In the valve–pump parallel control system, the introduction of valve control does not change the system natural frequency, but increases the total leakage coefficients and damping ratios, which vary widely with operating point. LVC is applied to improve low-speed stability by increasing total leakage coefficients and damping ratios. RVC is applied to accelerate the dynamic response to load disturbance. Compared with LVC, RVC has more stable damping ratio and speed stiffness, and its performance could be further improved by increasing the valve supply pressure.
Ding et al. 3.
The valve–pump parallel variable mode control establishes a flexible control mechanism, and control modes could vary with control requirements. The proposed method could improve the overall performance of a hydraulic motor speed system and offer good low-speed performance and a rapid response to load variation while maintaining a high system efficiency.
Declaration of conflicting interests
15
10.
11.
12.
13.
The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
Funding The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This work was supported by a Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions and the Fundamental Research Funds for the Central Universities (no. 2015QNA33).
References 1. Merritt HE. Hydraulic control systems. New York: John Wiley & Sons, 1967. 2. Manring ND. Hydraulic control systems. New York: John Wiley & Sons, 2005. 3. Karunanidhi S and Singaperumal M. Mathematical modelling and experimental characterization of a high dynamic servo valve integrated with piezoelectric actuator. Proc IMechE, Part I: J Systems and Control Engineering 2010; 224: 419–435. 4. Manring ND. Fluid power pumps and motors: analysis, design and control. New York: McGraw-Hill, 2013. 5. Chiang MH, Chen YN and Chen CC. A comparison of an AC-servo motor driving variable rotational speed and a variable displacement pump-controlled systems for velocity control. In: Proceedings of the 7th JFPS international symposium on fluid power, TOYAMA, 15–18 September 2008, pp.629–634. 6. Ding HG, Zhao JY and Zhao L. Analysis on electrohydraulic speed servo control schemes for anti-explosion hydraulic hoisters. J China Coal Soc 2011; 36: 1407–1411. 7. Lu YX. Historical and progress and prospects of fluid power transmission and control. Chinese J Mech Eng 2001; 37: 1–9. 8. Manasek R. Simulation of an electro-hydraulic load-sensing system with AC motor and frequency changer. In: Proceedings of the 1st fluid power net international PhD (FPNI-PhD) symposium, Hamburg, 20–22 September 2000, pp.311–324. 9. Shen HK, Jin B and Chen Y. Research on variable speed electro-hydraulic control system based on energy regulating strategy. In: Proceedings of the ASME international
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
mechanical engineering congress and exposition, Chicago, IL, 5–10 November 2006, pp.230–236. New York: IEEE. Shen HK, Jin B and Chen Y. Variable speed hydraulic control system based on energy regulation strategy. J Mech Eng 2009; 45: 210–213. Jin B, Shen HK and Chen Y. Energy-regulation based variable speed hydraulic cylinder position control system. J Mech Eng 2008; 44: 25–30. Qi XY, Fu YL and Wang ZL. Scheme analysis of power by wire airborne actuation system. J Beijing Univ Aeronaut Astronaut 1999; 25: 426–430. Cochoy O, Carl U and Thielecke BF. Integration and control of electromechanical and electrohydraulic actuators in a hybrid primary flight control architecture. In: Proceedings of the 1st international conference on recent advances in aerospace actuation systems and components, Toulouse, 13–15 June 2007, pp.1–8. Kang RJ, Jiao ZX and Wang SP. Design and simulation of electro-hydrostatic actuator with a built-in power regulator. Chinese J Aeronaut 2009; 22: 700–706. Wang SA, Lin TX and Shi WX. Research on control method for speed servo systems in high power hydraulic motors. J Xi’an Jiao Tong Univ 1991; 25: 100–108. Ma JG, Wang SF and Wang ZL. Research on speed servo system of hydraulic motor. Mach Tool Hydraulics 2002; 6: 98–102. Sheng WX, Wang SA, Lin TX, et al. New type of paralleled valve control hydraulic motor speed servo system. Mach Tool Hydraul 1993; 2: 69–72. Ding HG and Zhao JY. Characteristic analysis of pump controlled motor speed servo in the hydraulic hoister. Int J Model Identif Control 2013; 19: 64–74. Ding HG, Zhao JY and Li GZ. Analysis of valve-pump combined high power hydraulic speed regulation schemes. J China Coal Soc 2013; 38: 1703–1709. Park SH, Lee JM and Kim JS. Robust control of the pressure in a control-cylinder with direct drive valve for the variable displacement axial piston pump. Proc IMechE, Part I: J Systems and Control Engineering 2009; 223: 455–465. Achten P. Dynamic high-frequency behaviour of the swash plate in a variable displacement axial piston pump. Proc IMechE, Part I: J Systems and Control Engineering 2013; 227: 529–540. Alessandro R, Salvatore M and Nicola N. Modelling a variable displacement axial piston pump in a multibody simulation environment. J Dyn Syst: T ASME 2007; 129: 456–468. Karnopp D. Computer simulation of stick-slip friction in mechanical dynamic systems. J Dyn Syst: T ASME 1985; 107: 100–103. Liu LL, Liu HZ, Wu ZY, et al. An overview of friction models in mechanical systems. Adv Mech 2008; 38: 201–213. Armstrong-He´louvry B, Dupont P and Canudas de Wit C. A survey of models, analysis tools and compensation methods for the control of machines with friction. Automatica 1994; 30: 1038–1183.
16 26. Cheok KC, Hu H and Loh NK. Modeling and identification of a class of servomechanism systems with stick-slip friction. J Dyn Syst: T ASME 1988; 110: 324–328. 27. Ding Q and Zhai HM. The advance in researches of friction dynamics in mechanics system. Adv Mech 2013; 1: 112–131. 28. Bo LC and Pavelescu D. The friction-speed relation and its influence on the critical velocity of stick-slip motion. Wear 1982; 82: 277–289. 29. Yamada H, Hibi A and Ichikawa T. Investigation of the low speed stability of oil hydraulic motors: 3rd report, the case of pump-controlled axial piston motors. Trans Jpn Soc Mech Eng B 1986; 52: 1657–1664. 30. Wang XY, Fu YL and Wang XY. Analysis on the low speed performance of electrohydraulic servo motors in hydraulic simulator with three shafts. J Astronaut 1996; 17: 85–90.
Advances in Mechanical Engineering 31. Jiang YX. A study on the problem of low speed jump of servo systems. Acta Automat Sin 1982; 8: 136–144. 32. Zeng QS and Qin JC. Analysis on the low-speed function of turntable servo system. J Chinese Inert Technol 2001; 9: 64–69. 33. Wang XY and Liu QH. Investigation of mechanism of low speed in electrohydraulic position servomotor system. J Harbin Inst Technol 1993; 25: 60–68. 34. Wang MZ and Xie WM. An investigation into low speed stability of piston motors. J Gansu Univ Technol 1989; 15: 1–7. 35. Manring ND. The discharge flow ripple of axial piston swash-plate hydrostatic pump. J Tribol: T ASME 2004; 126: 511–518. 36. Yang HY, Zhang B and Xu B. Development of axial piston pump/motor technology. Chinese J Mech Eng 2008; 44: 1–8.