XL Keypad Menu Tree

10 downloads 277755 Views 105KB Size Report
Sep 1, 2012 ... Analog 1 Setup ->. Analog 1 = X.XXXX V ... Dig I/O 1 Setup ->. Digital I/O 1 = 1. Mode [Digital Input ]. Trg Fnt[0. ] ... SDI-12 Task Option ->. SDI-12 ...
XL SERIES KEYPAD MENU TREE (Page 1 of 3) Stage = X.XX

Scanning...

PtTemp =

Scanning...

XX.XX

Keyboard Operations

Battery= XX.XX Sensor Input Setup->

September 2012 Version 4.44

Stage Setup

->

Stage

[X.XXX ]

Offset [0.00

The ENTER Key has three functions:

]

Stage Units[Feet

]

I. Pressing the ENTER Key while in the "Stage =" or "Pressure =" fields will start making a pressure measurement of these parameters. This provides the user with a current stage and pressure reading.

Averaging Time [001] Datum [0.000] PtTmp Sensor Setup ->

Pt Temp Units[Deg C ]

Counter Setup

Counts

->

[X.XXX

Total Cnt

II. The ENTER Key enables you to open fields that can be modified or changed. These menus have a "[ ]" field in them. For Example, in the "" menu option there are three ouput options; "FLASH Card", "Chart Drive", or "Shaft Encoder". Each of these options can be changed to either "[ON]" or "[OFF]".

]

[X.XX

]

Reset Counters ? Ctr Slp[0.0100

III. The ENTER Key is used to accept edits or changes. For Instance, you have changed the STAGE Scalar from Slope: [+2.3067] to Slope: [0.70309] to change from feet to meters. You press the ENTER Key to accept this change.

]

Cnt Interval[Daily ] Ctr Mode[Count Only] Rate Win Size[15

The CANCEL Key has two functions:

]

Ctr Debounce [005]mS

*

Analog 1 Setup

->

Analog 2-4 Setup

->

I. The CANCEL Key works the same as the ESCAPE Key does on your computer. For example: you are editing a parameter and you decide not to make a change; you can press the CANCEL Key to abandon your edits.

Analog 1 = X.XXXX V Offset [0.000

]

Slope

]

[1.000

A1 Samples [500

]

Range

]

[5.0 V

II. The CANCEL Key also works as a homekey. Meaning, if you are in a sub-menu and wish to return to the upper menu, press the CANCEL Key. This also works if you wish to return to the top menu, the "Stage =" menu.

Differential Md [Off]

Frequecy Setup

->

Frequency = X.XXX Freq Slp[1.0000

The ARROW Keys (

]

Freq Ofst[0.0000 ]

**

Dig I/O 1 Setup

->

Dig I/O 2 Setup

->

I. The and ARROW Keys enable you to scroll from one menu to another. When you reach the bottom screen, the ARROW Key will no longer work. When you are at the top screen, the ARROW Key no longer works. Menus with a "->" on the right side of the display indicate that there are sub-menus associated to the current screen. Use the ARROW Key to access the sub-menus. Use the ARROW Key or CANCEL Key to exit a sub-menu.

Digital I/O 1 = 1 Mode [Digital Input Trg Fnt[0

]

]

Pulse Length [1000 ] WarmUp Delay [250

]

Test Quad Out? Encoder Setup

->

SDI Transparent

Enc Out Src [None

->

II. The and ARROW Keys enable you to scroll through the options within a menu. For example, you want to change the output option from "FLASH Card:[Off]" to "FLASH Card: [On]". You use the and ARROW Keys to make your selection.

]

Enc Iu Val[X.XXXX

]

Enc Iu Slp[0.01000

]

) have four functions:

III. When Editing numerical parameters, the and ARROW Keys also let you increase or decrease the flashing digit by one. They also toggle the "+" and "-" signs.

SDI-12 Test Adrs[0] Send Ack Cmd?

IV. The and ARROW Keys let you move the cursor back and forth across the screen when you are editing a numerical menu such as the slope and offset. The digit or blank space will flash to let you know where the cursor is.

Send ID Cmd? Send Verify Cmd? Send Measure Cmd? Send Data 0 Cmd? Send Extended Cmd? Ext Cmd[XX] Set SDI12 Line High? SDI-12 Task Option

->

SDI-12 Tasks Table

->

->

->

->

. . . Value

2 - 10

[0.00]

Use Tmout Valu [Yes}

Address

[0]

. . . Address

Parameter 1

[1]

. . . Parameter 2 – 10

[1]

Meas Type

[M]

. . . Meas Type 2 – 10

[M]

. . . Scan Task 2 - 10 2 - 10

[0]

ComPort 1

[SDI-12]

. . . ComPort

2 – 10

[SDI-12]

SDI-12 Test Adrs[0]

Slope 1

[1.00]

. . . Slope

2 – 10

[1.00]

H310 Stage [XX.XXX ]

Offset 1

[0.00]

. . . Offset

2 – 10

[0.00]

H310 Units[Ft

H-330 Setup

[0.00]

Scan Task 1

Reset to Defaults

H-310 Setup

Value 1

Timeout Val [0.00]

]

SDI-12 Test Adrs[0] H330 Stage [XXXXXXX] H330 Units [Ft CW

Output Options

->

Logging Options

]

->

Auto Print [Off]

GOES Options

Logging

Source 1

[Date ]

->

. . . Source 25

[Date ]

.NEW File [None]

[On ]

Header 1

[MM/DD/YY]->

. . . Header 25

[MM/DD/YY]->

Data Fmt

Log Rate 1 [HH:MM:SS]->

. . . Log Rate 25[HH:MM:SS]->

Digits 1

->

. . . Digits 25

Col 1 Fn() [Now ]

->

. . . Col 25 Fn()[Now ]

->

Stat Scrn 1[No ]

->

Stat Scrn 25[No ]

->

[Normal]

Report Options ->

->

[X ]

Radio Type [SE-1200]

ST Channel [000]

GOES Mode

[Off]

ST Rate

[HH:MM:SS]

GOES Time

[HH:MM:SS]

ST Offset

[HH:MM:SS]

GOES Adrs

[XXXXXXXX]

ST Baud Rate [300]

GOES Preamble [Short]

ST Window

Self Timed Options

Center Data [No]

->

[X ]

->

->

[15] Sec

ST Data Fmt [SHEF] Data Order

[SCAN]

Data First

[Newest]

Send SHEF Codes [No] Append Bat Value [No] Extra Data Sets [001] ST Data Opts

Random Options Next Txd:

->

N/A

Continued on Next Page

[None ] -> ->

. . . Source 25 . . . SHEF Code 25

[None ] ->

SHEF Code 1 [XX]

Txd Test Carrier?

MeasRate 1 [HH:MM:SS]-> . . . MeasRate 25 [HH:MM:SS]->

[XX]

Fmt 1 [XX.XX] ->

. . . Fmt 25 [XX.XX] ->

Source 1 [None]

. . . Source 5 [None]

RR Channel [000]

RR Baud Rate [100]

GOES Min V [10.00]

Continued on Next Page

Source 1

RR Rate [HH:MM:SS]

Next Tx At: N/A

Reset GOES Options?

->

ST Buffer Cnt = 0

Tx Fnt [XXXXXXXXXX] -> RR Data Opts

->

RR Buffer Cnt = 0 Transmit RR Data?

->

September 2012 Version 4.44

Continued From Previous Page

XL SERIES KEYPAD MENU TREE (Page 2 of 3)

Output Options (Continued)

->

Remote Display

->

Rem Display [None ] Rem Label [Stage = ] Rem Display Port [3]

Voice Modem

->

Alert Radio

->

Modem Type [H2191]

Box 1 Src [None]

. . .

Box 10 Src [None]

Voice Modem [Off]

Trg 1 [Off]

. . .

Trg 1 [Off]

Update Rt [HH:MM:SS]

Trig Pnt [1.000]

. . .

Trig Pnt [1.000]

Modem Source Setup

Reset Pt [0.000]

. . .

Reset Pt [0.000]

ALERT Radio[Off ] Tx OffSet [HH:MM:SS] ALERT Sensor Setup->

. . .

Source

ALERT ID 1 [0000] ->

. . .

ALERT ID 20 [0000]

Range [20.47]

. . .

Range

. . .

Divisor = 100.0

Source

1 [None]-> ->

Divisor = 100.0

[20.47]

. . .

Base = 0.00

mA Output = 4.000 4-20 Source [None]

Data Fnt 1[NOW]->

. . .

Data Fnt 20[NOW]

Txd Rate [8Hours] ->

. . .

Txd Rate

Max Value [20.000] Min Value [4.000]

Trg 1 [Off]->

. . .

Trg 20

Trig Pnt [1.00]->

. . .

Trig Pnt [1.00]

HoldOff 1 [015] ->

. . .

HoldOff 20 [015]

Override[2.00]->

. . .

Override[2.00]

Force ALERT 1 Txd?

. . .

Force ALERT 20 Txd?

Base 4-20mA Options ->

->

20 [None]

= 0.00->

[8Hours] [Off]

* Analog 2, 3, & 4 are the same menu structure as Analog 1, but don't include the "Differential Md [Off]" function. ** Dig I/O 2 Setup is the same menu structure as Dig I/O 1 Setup

Alarm Setup

->

Alarm Enabled [No ] Alarm Retries [0] Individual Setup ->

Source 1 [None] -> TRG 1 [Off] -> Set Pnt 1 [1.00]-> Rst Pnt 1 [0.00]-> ID Tag 1 [AL1 ]-> S# 1 [0

]->

Comm 1 [Direct ]-> Ph# 1[N/A Modbus Options

->

]->

Force Alarm 1?

Last Cmd At XX:XX:XX

->

... ... ... ... ... ... ... ... ...

Source 10 [None] T 10 [Off] Set Pnt 10 [1.00] Rst Pnt 10 [0.00] ID Tag 10 [AL10] S# 10 [0

]

COM 10 [Direct

]

Ph#10[N/A

Modbus Mode [Off] Modbus Address [001] Modbus Baud [19200 ] Modbus Parity [Even] Modbus TimeOut [030]

Data Options

->

Enter Device Mode? Int SD Memory OK SD Data Card OK USB Drive OK View Current File Copy Files

->

Opening File . . .

->

Erase Memory

->

Copy All 2 Ext Card?

Erase Single File Calc Bytes Free

->

->

Copy All 2 USB Drv? Cpy EXT SD 2 Int SD? Copy USB 2 Int SD? Copy .New 2 EXT SD? Copy .New 2 USB?

Erase Int. SD File? Erase Ext. SD File? Erase USB File? Erase Int.SD File? Erase Ext.SD File? Erase USB Drive? Int.SD Bytes Free? Scan Setup

->

Scanning [Off] Scan Rate [HH:MM:SS] Scan Ofst Tm [00:00] Next Scan = HH:MM:SS Nxt Scn At[HH:MM:SS] Start a New File?

Continue to Page 3

]

Force Alarm 10?

Ext.SD Bytes Free? USB Bytes Free?

September 2012 Version 4.44

Continued From Previous Page

XL SERIES KEYPAD MENU TREE (Page 3 of 3)

SignOn Msg [#Sign 0] Use PassWord [No

]

Password [#123

]

Sys TimeOut [300]Sec System Setup

AutoOff Enabled

Time [HH:MM:SS]

Side Button Setup ->

Date [MM/DD/YY] Date Fmt [MM/DD/YY] Sync[Sync Disabled]

+12VX On [Always ] User Mode [Normal

Sync Time Now?

Data Card Type = USG

Time Ofst [00:00:00] Site ID [Site_ID

] ->

]

Radio Type [SE-1200]

Last Synced On DD/MM

Advanced Options

Mode[Hold to Update]

Excite Warmup [00]Sec

Atmel Version = 1.09 Update Atmel SW?

Serial Port Setup -> Baud Rate Com1[9600] Baud Rate Com3[9600] StartUp1[Menu Mode] StartUp2 [Off ] SDI12 Sensor Setup

Sensor Mode Enabled Sensor Mode Adrs [0] SDI Par Par Par Par

Meas. Time [008] 1 Source[Stage] 2 Source[PSI] 3 Source[PtTemp] 4 Source[None]

StartUp3 [Off ] Flow Control [SW] Char Delay 1 [XXX] Line Delay 1 [XXX] Emulation [VT-100] Quiet Mode [Off] Quiet Mode Dur [XX]

Par 9 Source[None] Par 1 Digits[2] Par 9 Digits[2] Timeout Val [0.00

SDI12 Logger Setup

]

SDI12 Logger Mode ->

System Config Opts->

Adrs 0 M Type [M] ->

Adrs 9 M Type [M] ->

Adrs0 Port[SDI-12]->

Adrs9 Port[SDI-12]->

Adrs 0 Redirect[0]->

Adrs 9 Redirect[9]->

Copy Setups to Mem ? Copy Setups to Card? Copy Setups to USB? Load From Memory ? Load From Card ? Load From USB ? Reset to Defaults ?

Functions Options ->

XL-Basic Options

->

Update Firmware?

Fnt 1 [0

]

Fnt 40 [0

]

Ld From Int SD Card? Ld From Ext SD Card? Ld From USB Drive? Basic 2 Int SD Card?

Battery = XX.X

System Status ->

Volts

Basic 2 Ext SD Card?

Min Battery = XX.X

Basic 2 USB Card?

Max Battery = XX.X

XL-BASIC1 = X.XXX

System Resets = XX

XL-BASIC5 = X.XXX

Reset Stat Screens ?

Debug Stepping Off

Firmware Ver = 4.44 Run Checksum Test ? Hardware Ver=3.40 Serial # = S#XXXXXX *

Accessory Setup ->

Bubble Line Test?

Bubble Rate[60]/Min

Gas Purge Setup ->

Purge Presur[40]PSI

Look for H3553's? H3553 at adrs [X] ->

Stage

[X.XX]

Purge Time [70] Sec

Slope

[X.XXX]

Manual Purge?

Offset

[X.XXX]

Timed Prg [00] days Tank PSI = X.XX

Avg Time

[000]

Bubble Rate [000] Purge PSI [00]

Line PSI = XX.XX

Prg Sustain [000]

Purged XXX Times

Timed Prg

[00]

Tank PSI = X.XX Line PSI

= X.XX

Purge H3553 ?

Last Prg=MM/DD HH:MM