3-wire, PNP. Light or dark. XU2-B18PP340 (1). XU1-B18PP340 (2). XU9-
B18PP340 (2). XU8-B18PP340. XU5-B18PP340 programmable switching. 3-wire
, NPN.
Photo-electric detectors Osiris® universal detectors, design 18 Plastic or metal case, cylindrical, M18 x 1 threaded Solid state output Presentation
Plastic case
d.c. supply
Pre-cabled or plug-in connector Line of sight along case axis (1)
With sensitivity adjustment and stability LED è
Page 30117/4
Metal case
d.c. supply
Pre-cabled or plug-in connector Line of sight along case axis (1)
With sensitivity adjustment and stability LED è
Page 30117/6
a.c. or d.c. supply
Pre-cabled or plug-in connector Line of sight along case axis (1)
Page 30117/8 (1) Line of sight 90° to case axis possible using mirror adaptor accessory. 30117/2
Te
Photo-electric detectors Osiris® universal detectors, design 18 Plastic or metal case, cylindrical, M18 x 1 threaded Solid state output Common general characteristics, schemes Detection characteristics Nominal sensing distance
Thru-beam system : 15 m Reflex system : 4 m Polarised reflex system : 2 m Diffuse system : 10 and 40 cm
Environment Product certifications
è. UL, CSA
Ambient air temperature
Operation : - 25…+ 55 °C. Storage : - 40…+ 70 °C
Vibration resistance
25 gn, amplitude ± 2 mm (f = 10…55 Hz), conforming to IEC 68-2-6
Shock resistance
30 gn, duration 11 ms, conforming to IEC 68-2-27
Degree of protection
IP 67 conforming to IEC 529
Function table
Function
Output state (PNP or NPN) indicator (illuminated when detector output is ON)
Thru-beam and reflex systems No object present Object present in the beam in the beam
Diffuse system No object present in the beam
Object present in the beam
Light switching Dark switching
Schemes Wiring schemes (3-wire a) Pre-cabled versions Transmitter
Light switching (no object present) Thru-beam receiver & reflex Diffuse PNP output PNP output OG
+
BN VI BU
–
BN BK BU
Test
OG
+
BN
–
BK BU
NPN output
Dark switching (no object present) Thru-beam receiver & reflex Diffuse PNP output PNP output
+
BN
–
BK BU OG
NPN output
+
BN BK
+
BN BK
–
BU
BN
+
–
BK BU OG
–
+
BN BK
+
–
BU
NPN output
NPN output
OG
OG
+
BN BK
–
BU
BU OG
Plug-in connector versions Transmitter
Light switching (no object present) Thru-beam receiver & reflex Diffuse PNP output PNP output 2
+
1
1 2 3
Test
4 3
NPN output
–
1
+
1
+
–
4 3 2
–
4 3 2
–
2 1 4
+
1 4
+
–
3
Wiring schemes (2-wire c) Pre-cabled versions Transmitter
+
4 3
+
4
Dark switching (no object present) Thru-beam receiver & reflex Diffuse PNP output PNP output
2 1
NPN output
2 1
NPN output
–
3
Light switching (no object present) Thru-beam receiver & reflex Diffuse
NPN output
+
1 4
–
3 2
–
3 2
Dark switching (no object present) Thru-beam receiver & reflex Diffuse
BN
BN
BN
BN
BN
BU
BU
BU
BU
BU
Plug-in connector versions Transmitter
–
OG
Light switching (no object present) Thru-beam receiver & reflex Diffuse
Dark switching (no object present) Thru-beam receiver & reflex Diffuse
2
2
2
2
2
3
3
3
3
3
Attention : It is essential that a load be connected in series with the detector.
Te3 0 1 1 7 / 3
Photo-electric detectors Osiris® universal detectors. Plastic case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output With sensitivity adjustment and stability LED Accessories : pages 30180/2 to 30180/7
References, characteristics
Design 18 1
2
3
System
Thru-beam 1
Reflex 2
Polarised reflex 2
Diffuse 3
Type of transmission
Infra-red
Infra-red
Red
Red
Nominal sensing distance (Sn)
15 m (transmitter + receiver)
4 m (with 50 x 50 mm 2 m (with 50 x 50 mm 0.10 m reflector) reflector)
0.40 m
Infra-red
References of pre-cabled versions 3-wire, PNP
Light or dark programmable switching
XU2-B18PP340 (1)
XU1-B18PP340 (2)
XU9-B18PP340 (2)
XU8-B18PP340
XU5-B18PP340
3-wire, NPN
Light or dark programmable switching
XU2-B18NP340 (1)
XU1-B18NP340 (2)
XU9-B18NP340 (2)
XU8-B18NP340
XU5-B18NP340
0.150
0.095
0.095
0.075
0.075
Weight (kg)
References of plug-in connector versions 3-wire, PNP
Light or dark programmable switching
XU2-B18PP340D (1)
XU1-B18PP340D (2)
XU9-B18PP340D (2)
XU8-B18PP340D
XU5-B18PP340D
3-wire, NPN
Light or dark programmable switching
XU2-B18NP340D (1)
XU1-B18NP340D (2)
XU9-B18NP340D (2)
XU8-B18NP340D
XU5-B18NP340D
0.040
0.040
0.040
0.020
0.020
Weight (kg)
Complementary characteristics Connection
not shown under general characteristics (page 30117/3)
Pre-cabled
Diameter 4 mm cable, length 2 m, wire c.s.a. : 4 x 0.22 mm2 (3 x 0.22 mm2 for thru-beam transmitter)
Connector
M12 male connector, 4-pin (suitable extension cables and female connectors types 3, 4 and 5, see page 30182/2)
Materials
Case : PC/ABS ; lens : PMMA ; cable : PVC
Rated supply voltage
a 12…24 V with protection against reverse polarity
Voltage limits
a 10…30 V (including ripple)
Switching capacity (sealed)
≤ 100 mA with overload and short-circuit protection
Voltage drop, closed state
≤ 1.5 V
Current consumption, no-load
< 35 mA (reflex and diffuse) ; ≤ 50 mA (thru-beam)
Maximum switching frequency
500 Hz (thru-beam system : 400 Hz)
Delays First-up : ≤ 30 ms ; response : ≤ 1 ms ; recovery : ≤ 1 ms (thru-beam system : 1.5 ms) (1) Reference for both transmitter and receiver for thru-beam system detectors. (2) 50 x 50 mm reflector included with reflex system and polarised reflex system detectors.
Note : These products are equivalent to the discontinued XUB short case detectors. See cross-reference tables, pages 30191/2 and 30191/3. 30117/4
Te
Photo-electric detectors Osiris® universal detectors. Plastic case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output With sensitivity adjustment and stability LED indicator Curves, dimensions, schemes
Accessories : pages 30180/2 to 30180/7 Detection curves Thru-beam system
Reflex system
15
Ø 12 mm
T
Diffuse system (Sn = 10 cm)
Ø of beam cm
Ø of beam cm
T/R
R
10
m
15
T/R
6 4 2
Sn ≤ 15 m
2
0,2
-2 -4 -6
-15
3
4
Ø of beam cm 1,4 1
Diffuse system (Sn = 40 cm) Ø of beam cm T/R
2
1
1
m
1
2
10 cm
40 cm
-1 -1,4
-1
Sn ≤ 0,10 m
Sn ≤ 2 m (1)
Sn ≤ 0,40 m
Sn ≤ 4 m (2)
With reflector XUZ-C50 (1) Polarised reflex XU9-B18iP340 (2) Reflex XU1-B18iP340 Excess gain curves (ambient temperature : + 25 °C) Thru-beam system Reflex system
Object 10 x 10 cm 1 White 90% 2 Grey 18%
Object 20 x 20 cm 1 White 90% 2 Grey 18%
Diffuse system (Sn = 10 cm)
Diffuse system (Sn = 40 cm)
gain 500 300
gain
gain
50
50
30 20 15 10 7 5
30 20 15 10 7 5
3 2
3 2
gain 50
10
30 20 15 10 7 5
5
3
100 50
1 0,1 0,2 0,5 1 0,3 0,8
2 3
6 5
15 10 20 D (m)
1 0,1
2 1
0,25 0,5 1 0,7
2 34 5
With reflector XUZ-C50 1 Polarised reflex XU9-B18iP340 2 Reflex XU1-B18iP340 Dimensions i P340 XUi i -B18i
0,5 1
2
0,2
5
10
20 60 15 D (cm)
Object 10 x 10 cm White 90%
i P340 + XUB-Z0i (3) XUi i -B18i (1)
(2)
M18x1
(2)
(1)
R E
24
M18x1
1 0,1 0,2 0,5 1
2
15 40 10 20 60 D (cm)
5
Object 20 x 20 cm White 90%
12
4
1 0,1
10 D (m)
Cable connections (–) BU (Blue) (+) BN (Brown) (OUT) BK (Black) (Prog.) OG (Orange) (Test) VI (Violet) for thru-beam transmitter only
Ø4 24
34
24
50
55
80
i P340D XUi i -B18i 4
i P340D + XUB-Z0i (3) XUi i -B18i
(1)
M18x1
(2)
(1)
24
12
(2)
Connector schemes Connector pin view Transmitter Thru-beam receiver, reflex and diffuse 1 (+) 2
Test
34
24
M18x1
24
50
55 68
1 (+) 4
3 (–)
2 Programming
4 Output 3 (–)
95
(1) LED (2) Adjustment potentiometer (3) XUB-Z0i : mirror adaptor for reflecting beam through 90°, see page 30180/2 Beam break test (for thru-beam transmitter only) Beam made BN/1
+
Fixing nut tightening torque : < 4 N.m Connector tightening torque : 2 N.m Verification of correct operation Thru-beam and reflex systems
Beam broken BN/1
+ Signal 1,5 1 level 0,7
VI/2
VI/2
Red LED BU/3
–
BU/3
– – LED off
Optimum alignment
+
LED on
Te3 0 1 1 7 / 5
Photo-electric detectors Osiris® universal detectors. Metal case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output With sensitivity adjustment and stability LED Accessories : pages 30180/2 to 30180/7
References, characteristics
Design 18 3
2
1
System
Thru-beam 1
Polarised reflex 2
Diffuse 3
Diffuse with adjustable background suppression 3
Type of transmission
Infra-red
Red
Infra-red
Infra-red
Nominal sensing distance (Sn)
15 m (transmitter + receiver)
2m (with 50 x 50 mm reflector)
0.4 m
0.1 m (0.08…0.12 m)
References of pre-cabled versions 3-wire, PNP
Light or dark programmable switching
XU2-M18PP340 (1)
XU9-M18PP340 (2)
XU5-M18PP340
XU8-M18PP340 (4)
3-wire, NPN
Light or dark programmable switching
XU2-M18NP340 (1)
XU9-M18NP340 (2)
XU5-M18NP340
XU8-M18NP340 (4)
0.285
0.170
0.150
0.150
Weight (kg)
References of plug-in connector versions 3-wire, PNP
Light or dark programmable switching
XU2-M18PP340D (1)
XU9-M18PP340D (2)
XU5-M18PP340D
XU8-M18PP340D (4)
3-wire, NPN
Light or dark programmable switching
XU2-M18NP340D (1)
XU9-M18NP340D (2)
XU5-M18NP340D
XU8-M18NP340D (4)
0.155
0.095
0.075
0.075
Weight (kg)
Complementary characteristics Connection
not shown under general characteristics (page 30117/3)
Pre-cabled
Diameter 5 mm cable, length 2 m (3), wire c.s.a. : 4 x 0.34 mm2 (3 x 0.34 mm2 for thru-beam transmitter)
Connector
M12 male connector, 4-pin (suitable extension cables and female connectors types 3, 4 and 5, see page 30182/2)
Materials
Case : nickel plated brass, lens : PMMA, cable : PVC
Rated supply voltage
a 12…24 V with protection against reverse polarity
Voltage limits
a 10…30 V (including ripple)
Switching capacity (sealed)
≤ 100 mA with overload and short-circuit protection
Voltage drop, closed state
≤ 1.5 V
Current consumption, no-load
≤ 35 mA (reflex and diffuse) ; ≤ 50 mA (thru-beam)
Maximum switching frequency
500 Hz
Delays First-up : ≤ 15 ms ; response : ≤ 1 ms ; recovery : ≤ 1 ms (1) Reference for both transmitter and receiver for thru-beam system detectors. (2) 50 x 50 mm reflector included with polarised reflex system detectors. (3) Detectors available with 5 m cable. To order, add the suffix L5 to the reference selected from above. Example : detector XU9-M18PP340 with 5 m cable becomes XU9-M18PP340L5. (4) These detectors do not have stability LED.
30117/6
Te
Photo-electric detectors Osiris® universal detectors. Metal case, cylindrical, M18 x 1 threaded d.c. supply. Solid state output With sensitivity adjustment and stability LED Curves, dimensions, schemes
Accessories : pages 30180/2 to 30180/7 Detection curves Thru-beam system
Polarised reflex system
Ø of beam cm 15
T
Ø 12 mm 10
m
-2 -4 -6
-15
T/R
1
1
1
2
1
2
m
12 cm -1 Sn ≤ 0,10 m
Sn ≤ 0,40 m
With reflector XUZ-C50
Object 10 x 10 cm 1 White 90% 2 Grey 18%
Excess gain curves (ambient temperature : + 25 °C) Thru-beam system Polarised reflex system
Object 10 x 10 cm 1 White 90% 2 Grey 18% Variation of usable sensing distance S Diffuse system with adjustable background suppression Potentiometer at minimum
Diffuse system (Sn = 40 cm) gain
gain 10
10
B
30 20
10
10 8 5
1 1
3 2
A 0,01
1
0,1 3 4 5 6 8 10 15 20 30 50 0,1 D (m)
2
0,5
1
2
5
10 D (m)
With reflector XUZ-C50
1
10
(2)
(1)
55
(2)
RE
24
Diffuse system with adjustable background suppression Potentiometer at maximum
A 0,01
(2)
XUi-M18iP340D + ZUB-Z0i (3) 4 M18x1
(2)
(1)
55
24
12
(1)
71
24 80
0,11 0,15 0,12
S (m)
24
71 105
A-B : Object reflection coefficient Black 6 % Grey 18 % White 90 % Sensing range Non sensing zone (Matt surfaces)
24 117
92 (1) LED (2) Potentiometer Fixing nut tightening torque : 15 N.m Cable connections BU BN BK OG VI
S (m)
(1)
Ø4
80
XUi-M18iP340D 4 M18x1
0,07 0,1 0,08
B
XUi-M18iP340 + XUB-Z0i (3) 4 M18x1
Ø5
(–) (+) (OUT) (Prog.) (Test)
40 100 D (cm)
Object 10 x 10 cm White 90%
12
Dimensions XUi-M18iP340 4 M18x1
0,1 0,1
24
1
-
1
40 cm -1
Sn ≤ 2 m
gain 100 80 50
Ø of beam cm
T/R
0,2
Sn ≤ 15 m
Diffuse system with background suppression (Sn = 10 cm)
Ø of beam cm
Ø of beam cm 6 4 T/R 2
R 15
Diffuse system (Sn = 40 cm)
(Blue) (Brown) (Black) (Orange) (Violet) only applicable to thru-beam transmitter
Beam break test (for thru-beam transmitter only) Beam made BN/1 +
1 (+) 2 Test
1 (+)
4 3 (–)
2 Programming
4 Output 3 (–)
Verification of correct operation Thru-beam and reflex systems Signal 1,5 1 level 0,7 Red LED
– Beam broken
BN/1
+
LED off
Optimum alignment
+
LED on
VI/2
VI/2
BU/3
(3) XUB-Z0i : mirror adaptor for reflecting beam through 90°, see page 30180/2 Connector tightening torque : 2 N.m Connector schemes Connector pin view Transmitter Thru-beam receiver, reflex and diffuse
–
BU/3
–
Te3 0 1 1 7 / 7
Photo-electric detectors Osiris® universal detectors. Metal case, cylindrical, M18 x 1 threaded a.c. or d.c. supply. Solid state output With sensitivity adjustment Accessories : pages 30180/2 to 30180/7
References, characteristics
Design 18 1
2
3
System
Thru-beam 1
Polarised reflex 2
Diffuse 3
Diffuse with adjustable background suppression 3
Type of transmission
Infra-red
Red
Infra-red
Infra-red
Nominal sensing distance (Sn)
15 m (transmitter + receiver)
2m (with 50 x 50 mm reflector)
0.4 m
0.1 m (0.08…0.12 m)
References of pre-cabled versions 2-wire, 24…240 V
Light switching
XU2-M18MB230 (1)
XU9-M18MB230 (2)
XU5-M18MA230
XU8-M18MA230
Dark switching
XU2-M18MA230 (1)
XU9-M18MA230 (2)
XU5-M18MB230
XU8-M18MB230
0.285
0.170
0.150
0.150
Weight (kg)
References of plug-in connector versions 2-wire, 24…240 V
Light switching
XU2-M18MB230K (1)
XU9-M18MB230K (2)
XU5-M18MA230K
XU8-M18MA230K
Dark switching
XU2-M18MA230K (1)
XU9-M18MA230K (2)
XU5-M18MB230K
XU8-M18MB230K
0.155
0.095
0.075
0.075
Weight (kg)
Complementary characteristics Connection
not shown under general characteristics (page 30117/3)
Pre-cabled
Diameter 5 mm cable, length 2 m (3), wire c.s.a. : 2 x 0.5 mm2
Connector
Ø 12 male connector, 3-pin (suitable female extension cables types 6 and 7, see pages 30182/2 and 30182/3)
Materials
Case : nickel plated brass, lens : PMMA, cable : PVC
Rated supply voltage
a /c 24…240 V
Voltage limits
a/c 20…264 V (including ripple on a)
Switching capacity (sealed)
10…200 mA (4)
Voltage drop, closed state