Validation of Image-Based Method for Extraction of Coronary
Recommend Documents
May 31, 2001 - by the following extractants of the sequential extraction procedure: As adsorbed on goethite, 1 M NaH2PO4; arsenic trioxide (As2O3), 10 M HF; ...
Nov 26, 2008 - (HPLC-DAD). After the optimization of the extraction and separation parameters, the method was validated by evaluating the analytical curve, ...
Davis, oxazepam and HPLC grade methanol, ace- tonitrile were purchased from Aldrich. Instrumentation. The chromatographic system consisted of a pump ...
Sven et al (2003). [5] used Imidazole Derivatives as a ... Ruijnan et al (2006) [9], synthesis of chiral salen Zn(II) and its coordination with imidazole derivatives ...
Beer's law is obeyed over the range 0.15 -1.5 µg of uranium/ ml. ... HNO3, HF (48%), HC104, and other reagents were of ... crystallized from petroleum ether (90 -100 °C). ... Add. 10 ml of aluminum nitrate solution and 10 ml of ethyl acetate. Shake
extraction of DNA from bones using acoustic energy which can be ... Traditional methods for DNA extraction from bone require cutting and ... electronic solenoid.
Coronary Sinus Extraction for Multimodality Registration to guide Transseptal ... The CS is the main venous vessel of the heart, located in the sulcus between left ...
Apr 11, 2014 - Olanzapine in bulk and their pharmaceutical dosage forms. found in stress condition of ... Email: [email protected]. Received: 20 Aug ...
Chess L, Bock G.N, Mardiney R: Restoration of the reactivity of frozen stores human lym- phocytes in the mixed lymphocyte reaction and in response to specific ...
[11] CEN, âEN 1090-2+A1: Execution of steel structures and aluminium structures - Part 2: Technical requirements for steel structures.â European Committee for ...
Mar 6, 2017 - Validation of QuEChERS based method for determination of fenitrothion residues in tomatoes by gas chromatographyâflame photometric.
Maíra G. Nunes1 and Leticia L. C. Rodrigues1. 1 Instituto de Pesquisas Energéticas e Nucleares (IPEN). Comissão Nacional de Energia Nuclear (CNEN).
PA is a thiol drug used in treatment of cystinuria, certain forms of metal intoxication and progressive systemic sclerosis [2] and Wilson's disease by acting as a ...
Quick response code. [Downloaded free from http://www.phmethods.org on Wednesday, May 07, 2014, IP: 61.3.205.219] || Click here to download free Android application for this journal .... The Merck Index. 13th ed. Whitehouse Station,.
Kulhari A, Sheorayan A, Bajar S, Sarkar S, Chaudhury A and K Kalia R. 2013. Investigation of ... Deepak M, Sangli GK, Arun PC and Amit A. 2005. Quantitative ...
Jun 9, 2018 - across marine and freshwater systems.1â5 Recently, attention is beginning to ... studies have examined microplastics in soil11â14 and sludge samples ...... methods for MP detection: What can we learn from them, and why.
Pharm. Res., 2010, 2(3):223-229. 223. HPLC method validation for simultaneous estimation of madecassoside, asiaticoside and asiatic acid in Centella asiatica.
Development and Validation of a Method for Simultaneous Quantification of Seven Water-Soluble Vitamins in Pediatrics Syrup by UPLC-MS/MS. Harmita a.
Mehsana, Gujarat, India. ... Development and validation of ... May 07, 2014, IP: 61.3.205.219] || Click here to download free Android application for this journal ...
Sep 2, 2012 - northeastern states of Pernambuco and Alagoas [14], and subsequently ...... Mota RA, Brito MF, Castro FJ, Massa M: Mormo em eqüídeos nos estados de Pernambuco e ... Brasília: Diário. Oficial; 2004:7–10. Seção 1. 18.
Nov 13, 2014 - pharmaceutical dosage form and uses. ... control of pharmaceutical formulations containing bivalirudin by ..... Santen RJ, Harvey HA . Use of ...
Nov 5, 2008 - 10. Chen YW, Chen J, Chen QM, Li HT. Differential pulse-polarographic behaviour of biotin and its determination. Fenxi Ceshi Xuebao. 1998;.
Method for the validation of immunohistochemical staining using SCID mouse xenografts: Expression of CD40 and CD154 in human non-small cell lung cancer.
deney's form of the Bradley and Dudeney (1973) formula (see Dudeney, 1983) which works quite well for average (monthly median) conditions but can give ...
Validation of Image-Based Method for Extraction of Coronary
Abstract—An accurate analysis of the spatial distribution of blood flow in any organ must be based on detailed morphometry (diameters, lengths, vessel numbers, and branching pattern) of the organ vasculature. Despite the significance of detailed morphometric data, there is relative scarcity of data on 3D vascular anatomy. One of the major reasons is that the process of morphometric data collection is labor intensive. The objective of this study is to validate a novel segmentation algorithm for semi-automation of morphometric data extraction. The utility of the method is demonstrated in porcine coronary arteries imaged by computerized tomography (CT). The coronary arteries of five porcine hearts were injected with a contrast-enhancing polymer. The coronary arterial tree proximal to 1 mm was extracted from the 3D CT images. By determining the centerlines of the extracted vessels, the vessel radii and lengths were identified for various vessel segments. The extraction algorithm described in this paper is based on a topological analysis of a vector field generated by normal vectors of the extracted vessel wall. With this approach, special focus is placed on achieving the highest accuracy of the measured values. To validate the algorithm, the results were compared to optical measurements of the main trunk of the coronary arteries with microscopy. The agreement was found to be excellent with a root mean square deviation between computed vessel diameters and optical measurements of 0.16 mm ( 0.05, averaged for all five hearts). Furthermore, the rms error between the two measurements of all vessels is 0.16 mm (0.21 mm for LAD, 0.14 mm for LCX, and 0.11 mm for RCA) which is