15 Feb 2013 - A compact high vacuum heating chamber for in-situ x-ray scattering studies. Rev. Sci. ... In the growing field of in operando and in situ X-ray experiments, there exists a large disparity in the types of ..... (Parker Seals, Inc.). Typi
prototypes (e.g. PowerPoint, on-screen animations, ... SketchWizard makes it possible for the software ... often Wizard of Oz techniques are also used to.
[4] Tom Hopper, Fred Preston, âCompression to Gray-scale Fingerprint Imagesâ, pp 309-317, DCC 1992 Data Compression,. IEEE Computer Society Press, Los ...
focusing with the Sinar p2 can be accom- .... Sinar p2: The easiest sharpness
compensation, made possible by ..... the operating instructions as well as tips &.
Jun 18, 2013 - SMR Development based on Light Water Reactor. Technology. â Feasibility study for design development wa
Feb 4, 2008 - System 3® and Pentair Water Pool and Spa® are registered trademarks of Pentair Water Pool and Spa, Inc.
... in a new dimension. SIRIUS 3RK3 Modular Safety System – now also with AS-
Interface ... The newest member of our safety system: the new SIRIUS. 3RK3
Advanced ..... Switching frequency z at ... executable on PC/PG under. Windows ...
02. 01.O Firmie. YAWAL S.A.jest jednym z największych dostawców
architektonicznych systemów profili aluminiowych w Polsce. Firma oferuje
szeroką gamę ...
KEYWORDS. Early development, multiple stakeholders, modular abstract prototyping, software tool concepts, focus group sessions. 1. INTRODUCTION.
should be recorded in an effective manner and should be processed ... MODULAR ABSTRACT PROTOTYPING FOR MULTIPLE STAKEHOLDERS. 3 detailed ...
Optimal Design of High Dexterity Modular MIS. Instrument for Coronary Artery Bypass Grafting. Damien SALLE, Philippe BIDAUD and Guillaume MOREL.
Time Reference Scanning Beam Microwave Landing System (TRSB-MLS) for world-wide use. This paper ... MLS which is on the verge of implementation throughout the world including India. ..... "FEE bgcsoN ... flat and free of intrusions,.
Accompanying paper for talk at NOBUGS2002 conference, NIST, ... We have chosen to ultimately use the NeXus data format [5], and a draft. ISIS NeXus raw data file .... call other VIs and pass and return data just like functions etc. Ray of Light ...
SYSTEM INTEGRATION USING LIBERA BASE SOFTWARE. FRAMEWORK ....
adapters: Matlab and LabView scripts, web, EPICS. (EDM, pyEpics) [8], Tango ...
There was a problem previewing this document. Retrying... Download. Connect more apps... Try one of the apps below to op
Instrument System for Sequential Chemical .... (a) The physician-pathologist ... is used o specify analytical procedures. (follow-up tests) based on chemical.
15 Dec 2000 ... SYSTEM WIRING DIAGRAMS. Instrument Cluster Circuit, Standard. 1997 Saab
900. For DIAKOM-AUTO http://www.diakom.ru Taganrog ...
Miniaturized Instrument-Mounted Navigation System ... But especially for surgical quality management, navigation systems have a high potential as objective.
Instrument landing system ILS.pdf. Instrument landing system ILS.pdf. Open. Extract. Open with. Sign In. Main menu. Disp
Self repair: All the modules are the same, have the ... We have proposed a modular robotic system that has .... 7 (a)), a group of 18 modules gets over a wall by.
«automotive regime» virtually freed companies from investment risks. However, the ..... In Brazil, a chain of technical schools (Serviço Nacional de Apredizagem.
D. N. FOX, W. J. TEAGUE, AND C. N. BARRON. Naval Research ... Corresponding author address: William J. Teague, Naval Research. Laboratory, Code 7332 ...
Mar 11, 2012 ... Hosaynali Beygi, Z., Fischer, H., Harder, H. D., Martinez, M., Sander, R., Williams,
..... Taraborrelli, D., Lawrence, M. G., Butler, T. M., Sander, R., ...
... Military Systems: Addressing Challenges of Complex Systems. Interoperable Open Architecture Conference. Michael S. Moore. Kase J. Saylor. 27 April 2016 ...
Suzuki Outboard. Connected to the. NMEA 2000® compatible system, the
gauges can display real-time readings from compatible electronic probes and.
Modular Instrument System
SMIS Multi-Function Gauges
Engine Interface Cable and Power Cables
4” Multi-Function Gauge The 4” Multi-Function Gauge uses a state-of-theart high-contrast, dot matrix display to monitor real-time graphic and numerical digital data. When connected into the SMIS system, it can monitor all engine functions, Speedometer, Tachometer, GPS* and many others. 990C0-88164-KIT 4” multi-function gauge kit includes:
Suzuki Modular Instrument System (SMIS) uses an easy to connect and expandable cable system to transmit graphic and numerical data to MultiFunction gauges. This easy to set up and install system can be used with nearly any boat and DF9.9B thru DF300 Suzuki Outboard. Connected to the NMEA 2000® compatible system, the gauges can display real-time readings from compatible electronic probes and the exclusive SMIS engine interface to monitor all engine functions. (Engine Monitor with 4” gauge only).
4” Multi-Function Gauge Female Terminator Male Terminator NMEA “T” Power Cable Interface Cable
1 1 1 3 1 1
990C0-88162
4” Multi-Function Gauge (Gauge Only)
*GPS requires additional hardware.
2” Multi-Function Gauge The 2” Multi-Function Gauge is capable of all functions of the 4” gauge except Engine Monitoring Functions. When connected to the SMIS system, it a can be programmed to monitor all other functions. 990C0-88162 4” Multi-Function Gauge
2” Multi-Function Gauge Female Terminator Male Terminator NMEA “T” Power Cable Interface Cable 25’ Backbone Cable SMIS Adaptor
1 1 1 3 1 1 1 1
990C0-88150 2” Multi-Function Gauge (Gauge Only)
Trim Gauge Display
990C0-88150 2” Multi-Function Gauge
Dual Engine Tachometer Display
GPS Receiver Module GPS receiver module interface for display of accurate location and speed on Multi-Function Gauges. 990C0-88120
GPS Module
Suzuki Modular Instrument System Engine Interface Cable (not shown) The most important part of the SMIS data system. DF9.9B thru DF300 Suzuki Outboards can connect to the system using the exclusive SMIS Engine Interface. (Adaptor Cable also needed for DF150G/175G/200AP/250AP/300AP applications.) 990C0-88149
Engine Interface Cable
SMIS Adapters (not shown) Special Adaptor must be used with SMIS Engine Interface to connect the DF150G/175G/ 200AP/250AP/300AP Outboard to the system.
K8 Adapter(not shown) Required in order to put new style 990C0-88149 Interface cable on older system with blue connector. 990C0-88141
NMEA Adaptor Harness (not shown) Allows connection to other NMEA devices (Device NET). 990C0-88137 NMEA Device to Blue “T” 990C0-88029 Blue Device to NMEA “T”
Connection Hardware T-Connector
990C0-88131
Single Engine Adapter
T-Connectors link all compatible cable, data and sensor devices and can be easily secured.
990C0-88132
Dual Engine Adapter
990C0-88110 T-Connector
990C0-88133
Triple Engine Adapter
990C0-88132 x2
Quad Engine Adapter
Terminating Resistors
990C0-88136
SMIS Adaptor – to connect at engine SDS connector
120 ohm Terminating Resistors are required for any open cable ends in the system.
Connection Cable (not shown)
990C0-88113 Terminator – Female 990C0-88114 Terminator – Male
The Extension Cable is the mainline of the Suzuki Modular Instrument System. Data communication runs the length of the boat, capped at each end with a 120 ohm Terminating Resistor. NMEA 2000 compatible sensors or other devices can be added by the use of T-Connectors throughout the system.
Monitors fluid levels such as fuel, live well water level, etc. 10ft cable.
Fused(3A) lead connects extension cable to the power source.
Surface Water Temperature sensor. 10ft cable.
990C0-88112
990C0-88118
Temperature Sensor
Quad Power Node (not shown)
990C0-88119
Temperature Sensor – Thru Hull
Allows network to be powered from multiple power sources (key switch, accessory switch, etc…).
Pressure Sensor (not shown)
990C0-88130
34970-98J02 Water Pressure Kit
Single Power Cable
Quad Power Node
990C0-88139 Pressure Sensor DF70A/90A/300
Fuel Gauge Display 990C0-88120 GPS Module
990C0-88110 T-connector
Optional Instrument Trims Change the standard black bezel to suit your application. 4 different bezel finishes to choose from for 2” or 4” Multi-Function gauges.
990C0-88113 Terminating Register – Female
990C0-88021-6PK Chrome Bezel 4” (not shown) 990C0-88023-6PK White Bezel 4” (not shown) 990C0-88025-6PK Chrome Bezel 2” 990C0-88027-6PK White Bezel 2”
990C0-88114 Terminating Register – Male 990C0-88025-6PK Chrome Bezel 2”
6
990C0-88027-6PK White Bezel 2”
990C0-88136 Adapter Interface to SDS Port on Engine