www.ietdl.org Published in IET Circuits, Devices & Systems Received on 7th August 2007 doi: 10.1049/iet-cds:20089021
ISSN 1751-858X
Reply to: Practical voltage/current controlled grounded resistor with dynamic range extension In response to Prof. Senani comments to our paper entitled ‘Practical voltage/current controlled grounded resistor with dynamic range extension’, we wish to state that we were not aware of his previous work done in this area as referenced by his supplied list of references. We ourselves had a long list of references as much work has been done in this area. For this, the authors thank him for drawing it to our attention, given his work relies upon the same technique ‘Bisection of the drain-to-source voltage of the FET’. As such we would have cited it had we been aware of it. Therefore we welcome his drawing his previous work to our attention.
IET Circuits Devices Syst., 2008, Vol. 2, No. 5, p. 467 doi: 10.1049/iet-cds:20089021
B. Maundy1 S. Gift2 P. Aronhime3 1
Electrical Engineering Department, University of Calgary, 2500 University Drive NW, Calgary, Canada T2N 1N4 2
Electrical and Computer Engineering Department, The University of the West Indies, St. Augustine Campus, St. Augustine, Trinidad and Tobago, West Indies 3
University of Louisville, Electrical and Computer Engineering, 10 Eastern Parkway, Louisville, KY 40292, USA E-mail:
[email protected]
467
& The Institution of Engineering and Technology 2008