tutorial 7 â open and closed loop links - FreeStudy
Recommend Documents
Telemark university college. Department of process automation. N-3914 Porsgrunn, Norway. Fax: +47 35 57 52 50. Tel: +47 35 57 51 68. May 22, 2008. Abstract.
brings together the various elements covered in tutorials 2 and 3. It leads into more .... called the FULL SCALE DEFLECTION (f.s.d.). ... pressure gauge with a range 0 to 500 kPa and an accuracy of plus or minus 2% f.s.d. could have an error.
Open-Loop Feedback Control Policies in Long Term. Hydrothermal Scheduling. L. Martinez and S. Soares. AbstractâStochastic dynamic programming has ...
The general symbol for signals is θ but specific ... θ = 14 I where θ is in degrees and I in mA. ... A potentiometer produces 50 mV per degree of rotation of its shaft.
Sep 15, 2010 - Atlanta, GA, USA. 2 Department of ..... (2009)wrote custom software to allow high-speed ... are developing an in vitro closed-loop system.
Aug 19, 2005 - This realization is shown in figure 9. Monostable multivibrators were cascaded to obtain desired triggering instants. Pulses generated by the ...
Sep 7, 2011 - stress-induced central hypovolemia on regulation of heart rate via the arterial baroreflex remains unclear. We sought to comprehensively.
Sep 7, 2011 - critical for the regulation of blood pressure during orthostatic stress. However, studies have ... open-loop cardiac baroreflex characteristics during orthostatic stress. ... orthostatic stress, despite a decrease in stroke volume, as u
The existence of feedback loop in the baroreflex system makes it difficult to determine the open-loop transfer function characteristic of the central arc by which ...
TUTORIAL 2 .... The diagram shows the basic design of a reciprocating compressor. ... reciprocates drawing in gas, compr
A pulley system uses a flat belt of c.s.a. 500 mm2 and density 1300 kg/m3. The angle of lap is 165o on the smaller wheel
this test, the true SOC value is obtained by integrating the current with time (coulomb-counting). The battery was fully charged using constant current/constant ...
Some methods for consistent closed loop subspace system identification presented in the literature are analyzed and compared to a recently published ...
Sep 2, 2003 - Abstract The effects of diazepam on optokinetic nys- tagmus (OKN) eye movements were studied under closed-loop and open-loop conditions ...
Compared to other base metals, the refining options for aluminium during the final metallurgical ..... [16] LME London Metal Exchange, Special Contract Rules.
Balancing Closed and Open Loop CSI in. Mobile Satellite Link Adaptation. Alberto Rico-AlvariËno, Jesus Arnau and Carlos Mosquera. Signal Theory and ...
OPEN AND CLOSED-LOOP SYSTEM IDENTIFICATION. 199. In the time domain approach, a Gaussian distribution is assumed for the noise and the likelihood ...
*Associate Professor, Mechanical and Aerospace Engineering, Senior Member AIAA. â Professor .... the vehicle as the number of passengers changes. ..... Of course, our mathematical descriptions of the form (29) are only approximations.
Dec 15, 2015 - a neural network approach where each neuron is a different function of ..... using OpenCL, with the same neuron model and number of neurons ...
mulit-family apartments or condos, or small business recycling. ... Acceptable uses: Equipment purchase, vehicle purchas
the identification data set by the closed-loop system, coupled with a control-relevant prefilter, yields a model whose corresponding control system improves its ...
... Constantin JM, Roberto De AGC, Zhang M, Lu Q (2004) Mechanical ventilation in patients with acute ... The Acute Resp
OPEN AND CLOSED. ENDOTRACHEAL SUCTIONING. Experimental and human studies. Sophie Lindgren. Department of Anaesthesiology and Intensive Care.
Jul 21, 2015 - basal rate and CR settings (adjusted) used to initialize the zone-MPC artificial pancreas controller. Subject's followed their usual meal-plan and ...
tutorial 7 â open and closed loop links - FreeStudy
Gain Margin. ⢠Bandwidth (The frequency at which M = -3 db). ⢠Peak Magnification and the frequency at which it occurs. An example open loop plot is shown ...
TUTORIAL 9 – OPEN AND CLOSED LOOP LINKS
This tutorial is of interest to any student studying control systems and in particular the EC module D227 – Control System Engineering. On completion of this tutorial, you should be able to do the following.
• Explain the link between the gain of an open loop and closed loop system. • Define the Bandwidth of a system. • Explain and interpret M N Contours. • Explain and interpret the Nichols Chart.
If you are not familiar with instrumentation used in control engineering, you should complete the tutorials on Instrumentation Systems. You should complete the previous tutorials before attempting this one.
RELATIONSHIP BETWEEN OPEN LOOP AND CLOSED LOOP PLOTS
1.1 POLAR PLOT Consider again a closed loop system with unity feedback. The open loop transfer function is G(s) and the G(s) closed loop transfer function is G cl = G(s) + 1 A polar plot of the open loop transfer function is much easier to do than a plot of the closed loop system. The plot does, however, yield information of the closed loop gain. We can determine the vector for G(s) + 1 by simply adding 1 to all the points as shown below to give vector C.
Figure 1 Vector B is the same as vector C. The ratio A/B is the modulus of the closed loop transfer function at any given frequency ω. If this ratio was plotted against frequency it would be seen that it peaks at some critical frequency ωp. G(s) M = A/B = G cl = G(s) + 1 Similarly the phase angle difference between the two plots at any frequency is the phase angle of the closed loop function and this is called an N value. N = ∠G cl = ∠G(s) − ∠{G(s) + 1} The modulus of G+1 may be calculated with a bit of trigonometry and is:-
It can be shown that a plot of constant M and N produces circles such that: M M2 For constant M, the centre of the circle is at and the radius is 2 1− M 1 − M2 1 Where N = tanφ N2 Below is a polar plot of constant M and N values. The open loop plot may be superimposed on it and information about the closed loop found. The blue line shows a typical closed loop plot. At any point the Modulus and phase angle of the closed loop transfer function may be obtained from the points where it intersects the circles
For constant N, the centre of the circle is at -0.5, j0.5/N and the radius is 0.5 1 +
Figure 3 1.3 BANDWIDTH Bandwidth is a way of describing the performance of a system in respect of frequency response. At some frequency the magnification peaks. This might show on a Bode diagram like this.
On the Nichols chart, the open loop gain is plotted vertically in db and the phase angle horizontally in degrees. The M and N contours are superimposed on the chart. When the open loop plot is made, the following information may be obtained: • Phase Margin • Gain Margin • Bandwidth (The frequency at which M = -3 db) • Peak Magnification and the frequency at which it occurs. An example open loop plot is shown with these items marked on the plot. Each point on the plot corresponds to a certain frequency.
Plot the open loop response on the Nichols chart for a system with unity feedback and an open loop 5 transfer function G(s) = s(s + 2)(s + 3) Determine the following. The phase margin The gain margin The peak magnification and the frequency at which it occurs. The band width SOLUTION 5 1 1 G2 = and G 3 = Evaluate the gain and phase angles for G1 = s (s + 2) (s + 3) A suitable frequency range is 0.4 to 4 rad/s. K In general if we have the resulting gain and angle are n + Ts K ⎛ ωT ⎞ G db = 20log and φ - tan -1 ⎜ (See previous tutorial) ⎟ ⎝ n ⎠ n 2 + ω2T 2 Remember that gains in db are added.
Figure 6 The phase margin is 54o and the gain margin is 16 db. Peak magnification occurs at around ω = 0.8 and has a value of about 0 db. The bandwidth is the frequency where the plot crosses the -3 db contour and is about 1.3 rad/s.
1. Plot the open loop response on the Nichols chart for a system with unity feedback and an open loop 0.5 transfer function G(s) = (s + 0.5)(s + 0.2) Determine the following. The phase margin (58o) The gain margin (The plot reaches -180o at infinite frequency) The peak magnification and the frequency at which it occurs (0 db and 0.6 rad/s) The band width (about 1 rad/s) 2. Plot the open loop response on the Nichols chart for a system with unity feedback and an open loop 5 transfer function G(s) = (s + 0.5)(s + 1)(s + 1.5) Determine the following. The phase margin (17o) The gain margin (-4 db) The peak magnification and the frequency at which it occurs (12 db and 1.4 rad/s) The band width (about 2 rad/s)