Using Current Probes to Inject Pulses for Troubleshooting

21 downloads 1557 Views 512KB Size Report
Advanced Troubleshooting Techniques for Circuits and Systems This course ... A technique for using current probes to inductively couple pulses into circuits for ...
DEPARTMENT FOR

CONTINUING EDUCATION

Using Current Probes to Inject Pulses for Troubleshooting by Doug Smith Doug Smith presents practical courses at the University of Oxford in autumn and summer each year. 1.

High Frequency Measurements This course delivers practical knowledge for signal integrity design troubleshooting and verification that can be used immediately on the job. The course material contains many unique design tips and troubleshooting techniques.

2.

Advanced Troubleshooting Techniques for Circuits and Systems This course covers advanced techniques for troubleshooting design problems in laboratory and field installations. The techniques are applicable from tens of kHz to tens of GHz and can succeed when standard techniques of circuit debugging have failed.

3.

EMC Lab Techniques for Designers This course covers techniques for finding design issues that may cause EMC compliance problems early in the design cycle, long before an official EMC test. These techniques can find a wide range of potential EMC problems in a design on the lab workbench.

4.

Suspect Counterfeit Detection, Avoidance and Mitigation A review of how semiconductor and medical device packaging countermeasures utilize advanced material solutions.

(reprinted with permission from Doug Smith www.dsmith.org)

Figure 1 Experimental Setup with Current Probes and Current Loop

www.conted.ox.ac.uk/electronics

Abstract: A technique for using current probes to inductively couple pulses into circuits for troubleshooting designs is described. Significant voltages can be coupled in series with wires and cables. Coupled pulses of several tens of Volts are easy to achieve. This technique can be especially useful in troubleshooting ESD problems as well as other noise ralated problems in designs. Discussion: This Technical Tidbit could be considered an extension of my 1998 IEEE EMC Symposium paper "Current Probes, More Useful Than You Think". In that paper, current measurements were made in the frequency and time domain. In this Technical Tidbit, I am turning the current probe around and using it to inductively couple pulses into wires and cables. Bulk injection probes are usually used for signal injection, but they are large, heavy, and designed to handle tens of Watts or more of continuous high frequency power. In this case, I use a current probe for the same purpose but for pulses instead of continuous sinusoidal signals. Although the injected pulses have a high peak value, the average power is very low as the pulses used last tens of nanoseconds and are tens of milliseconds or further apart, allowing the use of current probes without worrying about heating of the probe. Figure 1 shows the experimental setup using a Fischer Custom Communications (FCC) TG-EFT pulse generator, an Agilent DSO5054A oscilloscope, an FCC F-65 current probe, and an FCC F-33-1 current probe. For the purposes of the experiments described in this Technical Tidbit, the pulses were coupled into the circuit from the pulse generator by an F-33-1 current probe and the resulting current measured with an FCC F-65 current probe. Figure 2 shows a view of the TG-EFT pulse generator.

Figure 2 Fischer Custom Communications TG-EFT Pulse Generator The TG-EFT pulse generator was set to 100 Volts open circuit for this test. The F-33-1 current probe is composed of several turns of wire around a magnetic core and essentially forms a transformer to the wire passing through it. This makes it ideal for injecting pulses. The F-65 current probe has internal networks to modify its sensitivity and frequency response. A probe such as this should not be used for injecting pulses except at low levels as the network may be damaged at higher pulse

www.conted.ox.ac.uk/electronics

levels. As a current probe the F-65 can handle 100 Ampere pulses resulting in a 100 Volt probe output. I have fed 100 Volt pulses from the TG-EFT into my F-65 with no ill effect as expected. In fact, Figure 1 shows the TG-EFT driving an F-65 with 100 Volt pulses. For a probe such as the F-33-1, insulation and saturation are the main considerations when feeding high voltage pulses into its BNC connector. I fed my F-33-1 as much as 400 Volt pulses from the TG-EFG with no saturation or breakdown resulting. The insulation on the windings in the probe is good so it should go even higher, although I did not test above pulse amplitudes of 400 Volts. Figure 3 shows the wire loop used for one of the experiments to follow. It is composed of AWG 16 stiff brass wire joined by a crimp connector at the ends to form a loop. The wire is covered with heat shrink tubing and forms a loop with about a seven inch (~17 cm) circumference.

Figure 3 Wire Loop Used for Pulse Injection Measurement In order to measure the value of the coupled open circuit voltage into circuits, an F-33-1 current probe was driven from the TGEFT and placed around the ground lead of an Agilent 1163a resistive divider probe. The 1163a probe has a 500 Ohm resistive input impedance (with around 1 pF of capacitance), a 10:1 probe attenuation factor, and a bandwidth in excess of 1 GHz. Figure 4 shows the test configuration. The probe's 500 Ohm input impedance reflects back through the current probe towards the generator as a much higher impedance in the many thousands of Ohms, so the test measures the open circuit injected voltage into a test circuit.

Figure 4 Measuring Open Circuit Voltage Injection Using an Agilent 1163a Resistive Divider Probe

www.conted.ox.ac.uk/electronics

Figure 5 shows shows the measured result from the circuit of Figure 4 with the TG-EFT generator set at 100 Volts. The peak voltage injected into the probe circuit is almost 10 Volts. I have tried the F33-1 up to 400 Volts from the TG-EFT with no ill effect, so series pulsed voltages around 40 Volts or more are possible into wires and cable using an F-33-1. If the winding on the F-33-1 were a single turn instead of several turns, the peak voltage would be higher, but the pulse width would be less because of reduced frequency response of the probe at the low end if the same magnetic core is used. The turns ratio of the F-33-1 gives the injected pulses a low impedance, ideal for launching pulses on a ground grid such as used in some facility grounding systems. A current probe with only one turn on its core might be better for injecting pulses on long cables, a higher impedance load.

Figure 5 Injected Open Circuit Pulse (vertical scale = 2 V/div, horizontal scale = 50 ns/div)

The 50 ns/div horizontal scale of Figure 5 is expanded to 10 ns/div in Figure 6 to show greater detail on the waveform. The small wiggles on the waveform are diminishing reflections between the current probe and the TG-EFT. Since the current probe is AC coupled, the area above zero Volts and below it must be the same. This is why the trace goes negative in Figure 5.

www.conted.ox.ac.uk/electronics

Figure 6 Injected Open Circuit Pulse (vertical scale = 2 V/div, horizontal scale = 10 ns/div)

Figure 7 shows the F-33-1 on the left injecting voltage into the wire loop of Figure 3 with the F-65 on the right connected to the oscilloscope. The output of the F-65 is shown in Figure 8.

Figure 7 F-33-1 as the Injection Probe and F-65 as the Sensing Probe

www.conted.ox.ac.uk/electronics

Figure 8 Measured Current in Wire Loop by F-65 Current Probe (vertical scale = 1/2 Amp/div, horizontal scale = 100 ns/div) Notice that the risetime of the current in Figure 8 is on the order of 20 ns whereas the injected voltage from Figure 6 is about 2 ns. The reason is the inductance of the wire loop. Remember that:

E(t) = L·di(t)/dt So we must integrate E(t)/L over time to get i(t) and therefore the current rises more slowly than the driving voltage. The larger the loop inductance of the wire loop, the lower the value of peak current given the time limited driving pulse from the TG-EFT. Summary: A method of using a pulse generator and a current probe to inject pulses of several tens of Volts in series with wires and cables is described. This method can be used to find ESD and other noise problems in equipment. A current probe consisting of only a winding and a magnetic core (and no internal networks) is best suited for pulse injection. The F-33-1 is widely available in the field and its turns ratio helps match a low impedance loop to the generator and feed coax making it a good choice. Pulses can also be injected from a pulse generator using standard bulk injection probes used for RFI immunity tests.

www.conted.ox.ac.uk/electronics

Doug Smith, MSEE Cal Tech, is the author of High-Frequency Measurements and Noise in Electronic Systems. His early career at Bell Laboratories led him to eventually become a member of the IEEE EMC Board of Directors and a prolific writer.

Doug Smith presents practical courses at the University of Oxford in autumn and summer each year. 1.

High Frequency Measurements This course delivers practical knowledge for signal integrity design troubleshooting and verification that can be used immediately on the job. The course material contains many unique design tips and troubleshooting techniques.

2.

Advanced Troubleshooting Techniques for Circuits and Systems This course covers advanced techniques for troubleshooting design problems in laboratory and field installations. The techniques are applicable from tens of kHz to tens of GHz and can succeed when standard techniques of circuit debugging have failed.

3.

EMC Lab Techniques for Designers This course covers techniques for finding design issues that may cause EMC compliance problems early in the design cycle, long before an official EMC test. These techniques can find a wide range of potential EMC problems in a design on the lab workbench.

4.

Suspect Counterfeit Detection, Avoidance and Mitigation A review of how semiconductor and medical device packaging countermeasures utilize advanced material solutions.

© Department for Continuing Education, University of Oxford Rewley House, 1 Wellington Square, Oxford OX1 2JA tel:+44 (0)1865 270360

www.conted.ox.ac.uk/electronics