PARALLEL INTERFACE KIT. The Parallel Interface Board adds one parallel
communication port. ("centronics:") to the standard serial communication port ...
EasyCoder 401/501/601 – Installation Instructions PARALLEL INTERFACE KIT Introduction Note: Illustrations show an EasyCoder 501. The principles for fitting this optional equipment in an EasyCoder 401 or 601 are exactly the same.
The Parallel Interface Board adds one parallel communication port ("centronics:") to the standard serial communication port ("uart1:"). Parallel communication is widely used for one-way communication between a computer and a single printer. As opposed to serial interfaces, the parallel interface requires no setup in the printer in regard of communication or buffers. 0
230V
"centronics:"
TA
"uart1:" Type Art. No. Ser. No. 115/230 V
2.6/1.3 A 50–60 Hz
MADE IN SWEDEN
When a Parallel Interface Board is fitted, the following types of interfaces become available: "uart1:" RS 232C RS 422 or 20 mA CL
Fitted on printer's CPU board. Standard. Option. Additional circuits required.
"centronics:" Fitted on Parallel Interface Board. Centronics parallel interface only.
The Parallel Interface Kit consists of: 1 Interface board assy. 2 Screws (not intended for EasyCoder 401/501/601) Installation Instructions
UBI EasyCoder 401/501/601 Parallel Interface Kit Installation Instructions Edition 2, January 1995 Article No. 1-960344-03 1
EasyCoder 401/501/601 – Installation Instructions PARALLEL INTERFACE KIT, cont'd. Step-by-Step Installation Instructions
The only tool required is a Torx #T10 screwdriver. ❑ Turn off the power and remove the power cord. ❑ Remove the communication cable from communication port "uart1:". Cover Plate 0
Power Switch
230V
Communication Port "uart1:"
Power Cord Receptacle
TA
Type Art. No. Ser. No. 115/230 V
2.6/1.3 A 50–60 Hz
MADE IN SWEDEN
❑
Open the right-hand door. ❑ Remove the six or eight Torx screws that hold the cover over the left part of the printer (see illustration below). ❑
Remove the cover. Screws
Cover
Ready
Power
Error
Setup Feed
F1
F2
F3
F4
F5
Enter
9
8
7
Pause
6
5
4
2
1 .
0
3 C
Print
Screws
Continued! 2
EasyCoder 401/501/601 – Installation Instructions PARALLEL INTERFACE KIT, cont'd. Step-by-Step Installation Instructions, cont'd. P-2 (external +5V)
Rear Plate
Parallel Interface Board (971,704,41)
Screw P2
Centronics Connector
S-1 S1
S3 S2
S-2/S-3
Screw
Connect to P-4 on CPU Board
❑
Warning! Be careful not to enable the external +5V unintentionally, which may cause harm to the terminal, computer, or other device connected to this port!
Remove the existing cover plate. ❑ Make sure that the CPU board is strapped and equipped for the desired type of communication on "uart1:" (see the EasyCoder 401, 501 or 601 Technical Manual). Once the interface board has been fitted, it will be difficult to access the rear part of the CPU board. ❑
If a +5V line (max. 200 mA) is desired on the parallel port, fit a jumper on P-2 on the Parallel Interface Board. Continued! 3
EasyCoder 401/501/601 – Installation Instructions PARALLEL INTERFACE KIT, cont'd. Step-by-Step Installation Instructions, cont'd.
❑
Select type of BUSY signal by means of straps on S-1 and S-2/S-3: • S-1: Strap = BUSY signal is on until end of ACK signal. No strap = ACK after BUSY signal (i.e., compatible to previous versions of this board). • S-2/S-3 (a jumper must be fitted on either S-2 or S-3): S-2 = BUSY signal on falling edge of /STROBE signal (i.e., according to specifications). S-3 = BUSY signal on rising edge of /STROBE signal (i.e., compatible to previous versions of this board).
❑
Connect the cable from the interface board to connector P-4 at the bottom rear corner of the CPU board. Be careful so the interface board and the CPU board do not come in contact with each other, which possibly may cause damage or short-circuiting.
❑
Fit the interface board assembly to the printer's rear plate from the inside as illustrated below using the same screws that held the removed cover plate.
❑
Reassemble the printer in reverse order. ❑ Connect the parallel communication cable to the Centronics connector. Please refer to page 5 for pinout descriptions. ❑
Connect the power cord and turn on the power.
Parallel Interface Board Assy. 0
230V
"centronics:"
TA
"uart1:"
Type Art. No. Ser. No. 115/230 V
2.6/1.3 A 50–60 Hz
MADE IN SWEDEN
Continued! 4
EasyCoder 401/501/601 – Installation Instructions PARALLEL INTERFACE KIT, cont'd. Step-by-Step Installation Instructions, cont'd. UBI offers a 3 metres (9.8 ft.) long ready-made parallel communication cable (36-p male Centronics – DB25 male). Article No. 1-010001-00
Connector Configuration
The connector is the standard female 36-pole Centronics type. The mounting holes are connected to chassis ground. Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14–15 16–17 18 19–30 31 32 33–35 36 37–38
Signal /STROBE DATA 0 DATA 1 DATA 2 DATA 3 DATA 4 DATA 5 DATA 6 DATA 7 ACK BUSY PE SELECT – GND + 5V GND /INPRM /ERROR – /SLCTIN GND
Dir. In In In In In In In In In Out Out Out Out – Out In Out – In
Remarks
See note! not used If strap fitted on P-2. Max. 200 mA.
not used Housing
Note: The PE signal (Paper End) on pin 12 requires an error-trapping routine to be included in the UBI Fingerprint software, activating the BUSY and READY statements. Here is an example on how such a routine may be written: 10 IF (PRSTAT AND 4) THEN GOSUB 1000 20 IF (PRSTAT AND 4) = 0 THEN GOSUB 2000 . . . . . . . . . . . . 1000 BUSY4 1010 RETURN 2000 READY4 2010 RETURN
Also see BUSY and READY statements and PRSTAT function in the UBI Fingerprint manual.
5
EasyCoder 401/501/601 – Installation Instructions NOTES
Information in this manual is subject to change without prior notice and does not represent a commitment on the part of UBI Printer AB. © Copyright UBI Printer AB, 1995. All rights reserved. Published in Sweden. EasyCoder is a trademark of United Barcode Industries (UBI). Centronics is a registered trademark of Centronics Data Computer Corp. Torx is a registered trademark of Camcar Division of Textron Inc. 6