2003 Chrysler PT Cruiser 2.4L built prior to September 25, 2002. (MDH 0925XX)
... 2003 Chrysler Voyager 2.4L RG equipped vehicles built prior to. January 6 ...
TECH TIPS Dixie Part Numbers:
Applications:
A-80006 S-80008 S-80040
A-80038 S-80009 S-80041
A-80039 S-80038
2003 Chrysler PT Cruiser 2.4L built prior to September 25, 2002 (MDH 0925XX) 2003 Chrysler Town & Country 2.4L built prior May 7, 2003 (MDH 0507XX) 2003 Chrysler Voyager 2.4L RG equipped vehicles built prior to January 6, 2003 (MDH 0106XX) and May 7, 2003 (MDH 0507XX) for RS equipped vehicles. 2003 Dodge Caravan 2.4L built prior to May 7, 2003 (MDH 0507XX) 2003 Dodge Neon 2.4L built prior to September 25, 2002 (MDH 0925XX)
Condition: The engine will not start or cranks for an excessively long time and shows false diagnostic codes in the system. Code may, among others, include: • P0016 - crankshaft/camshaft timing misalignment • P0335 - crank position sensor circuit. • P0339 - crankshaft position sensor circuit intermittent • P0340 - cam shaft position sensor • P0622 - alternator field not switching Note: Other false codes may be stored as well.
Cause: The PCM program may be out of date. Correction: Follow the manufacture’s recommended procedures for diagnosing the system and updating the PCM. NOTE: When updating the PCM other modules may require having the faults cleared as well. 20090601 Revised to limit scope to 2.4L engines and added in Voyager, Town and Country and Caravan applications 20100416 Updated part numbers listed 20100429 Removed SPD part numbers REV: 20100429 Courtesy of APRA TSB_814.doc Dixie Tech Tips are intended for use by professional technicians, and are not for the general public. They are written to inform technicians of conditions that may exist or as a guide to aid in diagnosing and servicing a vehicle. All references to original equipment manufactures, vehicle manufactures and any other Trade Mark names are for the sole purpose of identifying the vehicle and or part that the Tech Tip applies to. This document is property of Dixie Electric Ltd. and is not to be copied or distributed with out written permission.